0-5v and RS485 Inline dew point transmitter Resist condensation

Pemancar Kelembaban & Suhu Gaya Inline dirancang untuk pemantauan dan pengendalian lingkungan di bangunan industri, komersial, dan bangunan lainnya.

Barang: HG602-5C5R

Sorotan Produk:

  • Sensor dan sirkuit digital berkinerja tinggi, memastikan pengukuran yang akurat dan kompensasi suhu
  • Stabilitas dan keandalan jangka panjang yang baik
  • Sensor 100% yang dapat diubah di lapangan, tidak perlu kalibrasi ulang
  • Respon cepat
  • Beberapa Opsi Output Ganda:                                                                        1. Modbus RS485 +4 ~ 20mA RS485 + 0 ~ 5V / RS485 +0-10V
  • Port komunikasi Modbus: RTU,9.6k/19.2k/38.4k/57.6k/115.2kBaud
  • Kepala Filter: Baja tahan karat yang disinter, ukuran pori 60um, ukuran pori OEM Tersedia

SPESIFIKASI

ModelKeluaran (T: Suhu, H: Kelembaban, DP: Titik Embun)Kisaran Titik EmbunKisaran SuhuKisaran KelembabanMenahan Kondensasi
HG602-5C4R (RS485)T + H + DP (baca secara bersamaan)
+ (4 - 20 mA),
T - H - DP (pilih 1 dari 3)
-80 ~ 80°C
 (dapat diatur dalam kisaran)
-40 ~ 80°C0 ~ 100%RHTahan
kondensasi
KategoriSpesifikasi dan fitur teknis
Catu dayaDC 10V ~ 30V (disarankan catu daya 12V)
Pembuangan daya<0.1W
Kisaran titik embun-80 ~ 80°C (dapat diatur dalam kisaran)
Kisaran suhu-40 ~ 80°C
Kisaran kelembaban0 ~ 100%RH (disarankan <90%RH)
Keluaran analogSuhu, Kelembapan, Titik embun (pilih 1 dari 3)
Keluaran RS485Suhu, Kelembaban, Titik embun (baca secara bersamaan)
Akurasi tipikal (20°C, 50%RH, Satu atmosfer standar) 
Suhu±0.1°C
Kelembaban± 1.5%RH
Titik embun±2°C (di Udara atau N2)
Resolusi output digital0,01 ° C / 0,1 ° C dapat dipilih<br>0,01%RH / 0,1%RH dapat dipilih
Laju baud komunikasi1200, 2400, 4800, 9600, 19200, 115200 dapat diatur, standar 9600 pbs
Keluaran (Secara bersamaan)1 rute: 4 ~ 20mA (RL≤500Ω)<br>1 rute: RS485 Modbus-RTU
Frekuensi akuisisiRespons 1 detik tercepat, lainnya dapat diatur oleh PLC
Format byte8 bit data, 1 stop bit, tidak ada pemeriksaan
Tekanan16 bar

Produk Terkait

Ini adalah galeri untuk menampilkan gambar dari postingan sosial terbaru Anda

Blog

Why Standard Sensors Fail in High-Temperature Humidity Measurement ?

Why Standard Humidity Sensors Fail in High-Temperature Environments Quick Summary Standard humidity sensors are mainly designed for ambient or moderate industrial conditions. Under sustained high temperatures, steam, contaminants, and repeated thermal cycling, they can suffer from material degradation, measurement drift, condensation damage, and shortened service life. This article explains the most common failure mechanisms and

Baca Selengkapnya "

Why High-Temperature and Humidity Transmitters Are Critical for Industrial Drying Processes

How to Monitor Temperature and Humidity in High-Temperature Industrial Drying Processes Quick Summary Industrial drying processes used in pharmaceuticals, food production, chemicals, ceramics, and materials manufacturing require precise control of temperature and humidity. Even small deviations can cause product defects, excessive energy consumption, longer drying cycles, or equipment damage. This guide explains why high-temperature drying

Baca Selengkapnya "

200℃ High-Temperature Humidity Transmitter for Industrial Drying Ovens HG808-T

High-Temperature Humidity Transmitter for 200℃ Industrial Drying Ovens-HG808-T In many manufacturing processes, drying is more than just a step — it’s a decisive factor that directly affects product quality, production efficiency, and energy consumption. Whether you’re drying ceramics, powder materials, food ingredients, coatings, lithium battery materials, or industrial components, temperature and moisture inside the drying

Baca Selengkapnya "

Mengoptimalkan Dehumidifier dengan Pemantauan Suhu dan Kelembaban Tingkat Lanjut

Effective moisture management is essential in facilities where materials, equipment, and processes depend on controlled environmental conditions. While dehumidifiers play a central role, their performance—and efficiency—largely depends on accurate temperature and humidity monitoring. With advanced transmitters providing continuous, real-time environmental data, dehumidifiers can operate intelligently rather than blindly, ensuring consistent protection and optimal operating costs.

Baca Selengkapnya "

Bagaimana Cara Kerja Pemancar Kelembaban dan Suhu?

In short, Humidity and temperature transmitters measure and send environmental data to control systems. They are widely used in HVAC, pharmaceuticals, food processing, and cleanrooms where precise conditions are critical. Sensing: Built-in humidity and temperature sensors detect moisture and heat changes. Signal Conversion: The device converts raw signals into standard outputs like 4–20 mA or

Baca Selengkapnya "

Mengapa Memantau Suhu dan Kelembaban di Pengering Udara Berpendingin?

Introduction Compressed air is often referred to as the “fourth utility” in modern industry, alongside electricity, water, and gas. Yet, one of the most common issues facing compressed air systems is moisture. When untreated, moisture can lead to corrosion, blocked pipelines, damaged pneumatic equipment, and compromised product quality. To address this, refrigerated air dryers—commonly known

Baca Selengkapnya "

Melindungi Manufaktur Semikonduktor dengan Perangkat Pemantauan Suhu dan Kelembaban yang Presisi

1. Introduction The semiconductor industry operates under some of the most stringent environmental conditions of any manufacturing sector. As devices shrink to the nanoscale and production processes grow increasingly complex, maintaining precise control over environmental parameters—particularly temperature and humidity—has become critical to ensuring consistent quality and yield. Even slight fluctuations in temperature or humidity can

Baca Selengkapnya "

Bagaimana Pemancar Suhu dan Kelembaban Memastikan Ketepatan di dalam Ruang

Introduction In the world of environmental simulation and reliability testing, constant temperature and humidity chambers are indispensable tools across a wide range of industries—from electronics and pharmaceuticals to materials science and aerospace. These chambers are engineered to maintain a precisely controlled climate, ensuring stable temperature and relative humidity (RH) for extended testing cycles. But what

Baca Selengkapnya "

Hubungi Kami