Precision Monitoring Solution for Environmental Test Equipment and Constant temperature and humidity chamber
Главная " Temperature and Humidity Transmitter for Humidity Test Chambers
In humidity test chambers, maintaining stable and accurate environmental conditions is critical for reliable testing outcomes. Temperature and humidity transmitters play a central role by providing precise, real-time monitoring and feedback control. Here’s why they are indispensable:
Ensure Accurate Environmental Control
Continuously measure and transmit real-time temperature and humidity data to maintain tight control over test conditions.
Improve Test Reliability and Reproducibility
Help ensure that every test is conducted under consistent conditions, reducing variability and increasing data reliability.
Enable Automated Feedback Systems
Work with the chamber’s control system to automatically adjust heating, cooling, humidification, or dehumidification processes.
Support Compliance with Testing Standards
Provide the accuracy and traceability required to meet ISO, ASTM, or industry-specific testing protocols.
Protect Sensitive Products and Materials
Prevent exposure to unintended environmental deviations, especially important for electronics, pharmaceuticals, and composites.
Facilitate Data Logging and Quality Audits
Allow seamless integration with data acquisition systems for recording, traceability, and documentation.
Requirement Item | Описание |
Точность температуры | Typically ±0.1℃ to ±0.2℃; higher precision for pharmaceutical testing |
Точность измерения влажности | At least ±1.5%RH; high-end tests require ±1.0%RH or even ±0.8%RH |
Долгосрочная стабильность | One year or longer with minimal drift, reducing recalibration |
Время отклика | Humidity response time ≤10 seconds for fast system feedback |
Drift Control | Annual drift ≤1.0%RH to ensure test consistency |
Requirement Item | Описание |
High-Humidity Endurance | Reliable under 90–95%RH or near-saturation for extended periods |
Anti-Condensation Design | Coating or heater on sensor surface to prevent condensation |
Устойчивость к коррозии | Resistant materials required for pharma, chemical, and defense chambers |
Requirement Item | Описание |
Compact/Custom Design | Small form factor or OEM dimension options for tight space |
Способ установки | Supports wall-mount, embedded, threaded, flanged, or snap-in installation |
Sealing Performance | High-sealing at probe interface to maintain chamber air tightness |
Сменный зонд | Quick-plug for easy maintenance or replacement without full teardown |
Requirement Item | Описание |
Output Type | Supports 4–20mA, 0–10V, RS485 Modbus RTU and other industrial standards |
Anti-Interference Design | Shielded signal cables to ensure stable transmission |
Calibration Support | Multi-point or field calibration supported for long-term precision |
What We Can Do for You | HG808-H: Solution | HG808-C Pro: Solution |
1. Failure in high humidity environments | Designed for 40–95%RH; supports long-term operation in high humidity. Anti-condensation and anti-mold design with high protection rating to avoid moisture ingress. | Also supports stable high humidity operation. Optimized internal structure with strong anti-drift capability. |
2. Inadequate humidity точность affects control | Provides ±2%RH accuracy, suitable for general high-humidity control requirements. | ±0.8%RH ultra-high accuracy, ideal for pharmaceutical stability testing and precise electronics testing. |
3. Difficult probe installation | Supports various probe forms: direct insertion, extended hose, flange mount. OEM customization for embedded use. | Offers compact probe version for tight or sealed chamber installations. |
4. Signal compatibility issues | Supports analog (4–20mA / 0–5V / 0–10V) + Modbus RTU / RS485; compatible with PLC, environmental monitoring, and industrial control systems. | Same support with dual output, adaptable to different systems. |
5. Complex maintenance, long cycle | Industrial-grade housing: dust-proof, corrosion-resistant, long maintenance-free period. Probe can be calibrated or replaced. | Minimal accuracy drift, supports multi-point calibration, reduces maintenance cost. |
6. Cost control and delivery issues | Uses domestic components. 40–60% cost savings compared to Rotronic/Vaisala. Fast OEM delivery. | Also cost-effective and suitable as a high-precision domestic alternative. |
Application Positioning | Product | Recommended Use Scenarios |
High-Humidity Specialized Model (Cost-Effective) | HG808-H | High-humidity fermentation chambers, food steam cabinets, constant temperature and humidity chambers, environmental aging chambers |
High-Precision Humidity Control (Imported Alternative) | HG808-CPro | Pharmaceutical stability test chambers, electronic temperature & humidity reliability test chambers, high-precision inspection chambers |
HENGKO предлагает широкий ассортимент датчиков температуры и влажности для любых задач, от датчиков температуры и влажности из нержавеющей стали до датчиков точки росы. Наши датчики точны, надежны и долговечны, что делает их идеальными для широкого спектра применений
HENGKO предлагает широкий ассортимент датчиков температуры и влажности для любых задач, от датчиков температуры и влажности из нержавеющей стали до датчиков точки росы. Наши датчики точны, надежны и долговечны, что делает их идеальными для широкого спектра применений
Monitoring temperature and humidity is essential at multiple stages of the operation of a constant temperature and humidity chamber (climate chamber) to ensure accurate simulation of environmental conditions and compliance with testing standards. The key processes that require real-time temperature and humidity monitoring include:
Purpose: To bring the chamber environment to the target temperature and humidity setpoint before introducing test samples.
Monitoring Role: Sensors verify that the chamber has reached the desired stable condition (e.g., 25°C ±0.2°C / 60%RH ±2%RH) before testing begins.
Purpose: To expose materials, products, or components to precise and stable environmental conditions over a defined duration.
Monitoring Role: Continuous feedback from temperature and humidity transmitters allows the control system to make fine adjustments. This ensures uniformity and prevents deviations that could invalidate test results.
Purpose: To record environmental data for quality assurance, regulatory compliance (e.g., FDA, ICH, ISO), and traceability.
Monitoring Role: Transmitters provide high-resolution, time-stamped data to the chamber’s data logger or external system to verify environmental conditions throughout the test duration.
Purpose: To automatically regulate heating, cooling, humidification, and dehumidification systems.
Monitoring Role: Real-time data from the sensors is used by the PID control algorithm to maintain tight environmental tolerances, responding to internal or external fluctuations.
Purpose: To detect deviations or failures (e.g., heater/humidifier malfunctions or door leaks).
Monitoring Role: The transmitter triggers alarms when temperature or humidity values fall outside of acceptable limits, helping prevent damage to test samples and ensuring system reliability.
Purpose: To maintain sensor performance over time and ensure test validity.
Monitoring Role: Monitoring trends in sensor drift or inconsistency helps schedule timely recalibration and reduce unplanned downtime.
Here are 5 factors you should consider when buy a humidity transmitter for your Climate Chambers:
Look for ±1.0%RH or better and ≤1%RH/year drift to ensure reliable test data.
Must operate long-term in 90–95%RH. Anti-condensation coating and corrosion-resistant housing are essential.
Response ≤10s helps maintain tight control via closed-loop feedback systems.
Supports 4–20mA, 0–10V, or RS485 Modbus to fit your control and monitoring systems.
Compact probes, replaceable elements, and field calibration save time and reduce downtime.
A temperature and humidity transmitter is a critical component in humidity test chambers, responsible for accurately monitoring and transmitting real-time environmental data. It helps maintain the desired climate conditions by feeding precise temperature and humidity readings to the chamber’s control system. This ensures consistency, repeatability, and compliance with testing standards, especially in industries like pharmaceuticals, electronics, and materials testing.
For high-reliability applications such as pharmaceutical stability testing or electronic component reliability, humidity transmitters should offer an accuracy of ±1.0%RH or better, with premium models achieving ±0.8%RH. Temperature accuracy should typically be within ±0.1°C to ±0.2°C. The sensor must also demonstrate low drift over time (≤1.0%RH/year) and fast response times (≤10 seconds) to meet strict control requirements.
Common failure risks include:
Condensation buildup on the sensor element, causing reading errors or corrosion.
Microbial growth due to prolonged exposure to high moisture.
Signal drift or loss of calibration over time.
Ingress of water vapor damaging internal electronics.
To mitigate these risks, industrial-grade transmitters are designed with anti-condensation coatings, sealed housings, sensor heaters, и corrosion-resistant materials (e.g., 316L stainless steel or PBT enclosures).
No, standard HVAC humidity transmitters are typically not suitable for the rigorous and high-humidity operating conditions of climate or test chambers. They often lack the necessary:
Measurement accuracy
Environmental sealing
Condensation protection
Долгосрочная стабильность
Industrial or laboratory-grade transmitters are specifically designed to operate in 90–95%RH, with strong resistance to drift, corrosion, and electrical interference, making them essential for reliable test chamber operation.
The most commonly used output signals include:
Analog outputs: 4–20mA or 0–10V, suitable for direct connection with PLCs or analog controllers.
Digital outputs: RS485 with Modbus RTU protocol, allowing for long-distance, multi-point data collection and integration with modern data logging systems.
A dual-output model (e.g., analog + Modbus) is often preferred for flexible integration and redundancy.
Calibration frequency depends on the application, sensor stability, and regulatory requirements. In general:
High-precision applications (e.g., pharmaceutical stability chambers): calibrate every 6–12 months.
General industrial use: annual calibration may suffice if the sensor is stable.
Choose transmitters with low drift specifications, multi-point calibration support, и field calibration options to minimize downtime and ensure traceability.
Компания HENGKO - мировой лидер в области промышленных датчиков, имеющий репутацию производителя уникального дизайна и превосходных эксплуатационных характеристик. Наши датчики температуры и влажности используются в самых разных отраслях промышленности, включая производство продуктов питания и напитков, фармацевтику, производство и мониторинг окружающей среды.
HENGKO - известный поставщик решений для мониторинга температуры и влажности для различных отраслей промышленности, специализирующийся на производстве современных датчиков и сенсоров температуры и влажности.
Сообщите нам по WhatsApp