High temperature and humidity Split Probe portable dew point temperature meter

The HENGKO HG-982 Handheld Dewpoint Meter is a versatile tool designed for spot-checking applications and field calibration in various industrial settings. It provides accurate and fast measurements of dew point, temperature, relative humidity, and wet bulb temperature.

Föremål: HG982

Produktparametrar

  • Temperaturområde: -30℃~+120℃ max, for the probe
  • Område för luftfuktighet: 0%RH-99.9%RH
  • Daggpunktsintervall: -50 ~ 80 °C (-58 ~ 176 °F)
  • Noggrannhet för extern sond: ±1,5%RH, ±0,4℃(25℃)
  • Webbredd: -20~60℃, ±0.5℃(25℃)
  • Flera måttenheter: °C, °F, ppm, g/m³, g/kg
  • Stor bakgrundsbelyst LCD-display: Lättläst i alla ljusförhållanden
  • Dataloggning och export: Gör att du kan lagra och analysera dina data
  • Datalagring: 32000-64000
  • Datautmatning: USB-kontakt, 99-Data kan användas direkt 
  • Kompakt och bärbar design: Enkel att använda på plats och i fält
  • Robust och hållbar konstruktion: Byggd för att klara tuffa industriella miljöer

SPECIFIKATION

Produktens höjdpunkter:

Snabb respons, produkten använder en sond i 316L rostfritt stål
Skalet är mer hållbart;
Med IP66-klassning för vattentäthet och dammtäthet kan den överleva tuffa förhållanden
Ger långsiktig noggrannhet under miljöförhållanden;
Enkelt gränssnitt, lätt att använda, lätt att använda, inget behov av professionell
professionell personalutbildning;
Den har också en högupplöst storbildsskärm med bakgrundsbelysning, vilket gör att produkten sticker ut även under den brännande solen.
Data kan visas normalt även i mörka nattmiljöer;
Anslut till Bluetooth, övervaka data i realtid och generera data automatiskt
Datatabellen kan lagra 99 uppsättningar data.

handhållen temperatur- och luftfuktighetsmätare instruktion
Bärbar temp- och luftfuktighetsmätare Artikelalternativ av HENGKO

VANLIGA FRÅGOR

A split probe portable dew point temperature meter is a precision instrument designed to measure dew point, temperature, and humidity in environments characterized by high temperature and humidity levels. The device consists of two main components: a sensor probe and a display unit. The sensor probe, equipped with specialized sensors, is placed in the measurement environment while the display unit provides readings and controls.

The dew point is determined by cooling a mirror surface until condensation forms, at which point the temperature of the mirror is recorded as the dew point. The meter calculates relative humidity, absolute humidity, and other parameters based on the dew point and temperature measurements. These instruments often employ advanced algorithms and compensation techniques to ensure accurate readings in challenging conditions.

High temperature and humidity split probe dew point meters find applications in various industries where precise moisture control is critical. Some common applications include:

  • Industriella processer: Monitoring and controlling humidity in manufacturing processes, drying, and curing operations.
  • HVAC-system: Optimizing system performance, preventing condensation, and ensuring indoor air quality.
  • Pharmaceutical and biotechnology: Maintaining controlled environments for product stability and safety.
  • Food processing: Monitoring moisture content in products and preventing spoilage.
  • Meteorology and environmental monitoring: Measuring atmospheric humidity for weather forecasting and climate studies.

Choosing the right dew point meter depends on specific application requirements. Key factors to consider include:

  • Temperatur- och luftfuktighetsintervall: Ensure the meter’s specifications match the environmental conditions.
  • Noggrannhet: Select a meter with the required precision for your application.
  • Probe length and material: Consider the distance between the sensor and display unit, as well as the probe’s compatibility with the environment.
  • Data logging capabilities: Determine if data recording and storage are necessary.
  • Display features: Evaluate the clarity and functionality of the display.
  • Calibration and maintenance requirements: Assess the ease of calibration and ongoing maintenance.

Calibration is essential for maintaining the accuracy of a dew point meter. The calibration process typically involves using a traceable humidity standard to adjust the meter’s readings. It’s recommended to follow the manufacturer’s calibration procedures and use certified calibration equipment. Regular calibration intervals should be established based on the meter’s usage and the criticality of the measurements.

Proper care and maintenance prolong the life and accuracy of the meter. Key maintenance practices include:

  • Regular cleaning of the sensor probe to prevent contaminants from affecting measurements.
  • Protecting the meter from physical damage and extreme environmental conditions.
  • Storing the meter in a controlled environment when not in use.
  • Following the manufacturer’s recommended maintenance schedule.

Relaterade produkter

Detta är ett galleri för att visa upp bilder från dina senaste sociala inlägg

Bloggar

Kontakta oss

sv_SESwedish

KONTAKTA OSS

För alla frågor är du välkommen att kontakta oss på