Stable and Accurate Dew Point Monitoring for Industrial and Environmental Applications
The HG602-D is a compact, high-reliability transmitter for dew point, temperature, and humidity measurement in environments up to 60 °C (140 °F).
-It delivers ±2 °C Td accuracy, fast response, and long-term stability, making it ideal for compressed air systems, HVAC monitoring, and industrial drying processes.
-The sensor’s condensation-resistant design ensures accurate readings even under high humidity or fluctuating ambient conditions.
Key Highlights:
*Operating Temperature: −40 ~ +60 °C
*Dew Point Range: −60 ~ +60 °C (−76 ~ +140 °F)
*Accuracy: ±2 °C Td (±3.6 °F)
*Output Options: RS-485 (Modbus-RTU) + 4–20 mA / 0–5 V / 0–10 V
*Condensation Resistance: Sensor remains dry and stable under high humidity
*Wide Power Supply: 10 – 28 V DC with polarity protection
*Strong Compatibility: Standard Modbus protocol for seamless system integration
Ideal for:
Compressed Air | HVAC | Industrial Drying | Environmental Control
📩 Contact us to customize your HG602-D dew point monitoring solution today.
| Modell | Kimenet (T: hőmérséklet, H: páratartalom, DP: harmatpont) | Harmatpont tartomány | Hőmérséklet tartomány | Páratartalom tartomány | Ellenáll a kondenzációnak |
|---|---|---|---|---|---|
| HG602- D | T + H + DP (egyidejűleg olvasható) + (4-20 mA), T - H - DP (válasszon 1-et a 3 közül) | -60 ~ +60°C (a tartományon belül állítható) | -40 ~ 60°C | 0 ~ 100%RH | Y |
🔹Features
| Kategória | Műszaki specifikációk és jellemzők |
|---|---|
| Tápegység | DC 10V ~ 30V (12V-os tápegység ajánlott) |
| Teljesítményleadás | <0.1W |
| Harmatpont tartomány | -60 ~ +60°C (a tartományon belül állítható) |
| Work Temperature range | -40 ~ +60°C |
| Páratartalom tartomány | 0 ~ 100%RH ( <90%RH ajánlott) |
| Analóg kimenet | Hőmérséklet, páratartalom, harmatpont (válasszon 1-et a 3 közül) |
| RS485 kimenet | Hőmérséklet, páratartalom, harmatpont (egyidejűleg olvasható) |
| Tipikus pontosság (20°C, 50%RH, Egy szabványos légkör) | |
| Hőmérséklet | ±0.1°C |
| Harmatpont | ±2 °C (±3.6℉)Td Accuracy (Dew Point) |
| Páratartalom | ±1,5%RH |
| Digitális kimeneti felbontás | 0,01°C / 0,1°C választható<br>0,01%RH / 0,1%RH választható |
| Kommunikációs baud-ráta | 1200, 2400, 4800, 9600, 19200, 115200 beállítható, alapértelmezett 9600 pbs |
| Kimenet (egyidejűleg) | 1 útvonal: (RL≤500Ω)<br>1 útvonal: RS485 Modbus-RTU Modbus kommunikációs port: RTU,9.6k/19.2k/38.4k/57.6k/115.2kBaud |
| Gyűjtési gyakoriság | A leggyorsabb 1s válasz, a többi beállítható a PLC által |
| Byte formátum | 8 adatbit, 1 stopbit, ellenőrzés nélkül |
| Nyomás | 16 bar |
Rendelési szám :
| Modell | Jel kimenet | Kimeneti érték | Harmatpont tartomány | Hőmérséklet-tartomány |
|---|---|---|---|---|
| HG602-D4 | 4-20 mA + RS485 | Harmatpont | -60 és 60 °C között | -40 to60 °C |
| HG602-D5 | 0-5v + RS 485 | Harmatpont | -60 és 60 °C között | -40 to 60 °C |
| HG602-D1 | 0-10v + RS 485 | Harmatpont | -60 és 60 °C között | -40 to 60 °C |
Ez egy galéria a legutóbbi közösségi bejegyzéseidből származó képek bemutatására.
Humidity measurement is relatively straightforward at ambient conditions. Most standard sensors perform adequately in offices, warehouses, and general HVAC environments. However, once temperatures rise above
Industrial drying processes—used in pharmaceuticals, food, chemicals, and materials—demand precise control of temperature and humidity. Deviations can lead to product defects, energy waste, or even
High-Temperature Humidity Transmitter for 200℃ Industrial Drying Ovens-HG808-T In many manufacturing processes, drying is more than just a step — it’s a decisive factor that
Effective moisture management is essential in facilities where materials, equipment, and processes depend on controlled environmental conditions. While dehumidifiers play a central role, their performance—and
Röviden, a páratartalom- és hőmérséklet-jeladók mérik és küldik a környezeti adatokat a vezérlőrendszereknek. Széles körben használják őket a HVAC, a gyógyszeripar, az élelmiszer-feldolgozás és a tisztaterek területén.
Miért kritikusak a szárító harmatpontmérők a sűrített levegős rendszereknél? Talán Mindig a sűrített levegőben lévő rejtett nedvességgel küzd, amely korróziót, fagyást okozhat,
Miért túl párás az egyik irodai zóna és hogyan javítja meg egy páratartalom-jeladó a helyzetet A tartós páratartalom egy irodai zónában megzavarhatja a kényelmet, növelheti a penészesedést.
Bevezetés A sűrített levegőt gyakran nevezik a modern ipar "negyedik közművének" a villamos energia, a víz és a gáz mellett. Mégis, az egyik leggyakoribb
1. Bevezetés A félvezetőipar a legszigorúbb környezeti feltételek mellett működik a gyártóiparban. Ahogy az eszközök a nanoméretűre zsugorodnak és a
Bevezetés A környezeti szimuláció és a megbízhatósági tesztek világában az állandó hőmérsékletű és páratartalmú kamrák nélkülözhetetlen eszközök az iparágak széles körében - az elektronikai
WhatsApp minket