Dew Point Transmitter Sensor - HG602-D
Strona główna " Portfolio " Wysokiej dokładności wbudowany czujnik punktu rosy 4-20mA HG602-D

HG602-D Dew Point Transmitter (Up to 60 °C) for Industrial Air Compressors
Stable and Accurate Dew Point Monitoring for Industrial and Environmental Applications
The HG602-D is a compact, high-reliability transmitter for dew point, temperature, and humidity measurement in environments up to 60 °C (140 °F).
-It delivers ±2 °C Td accuracy, fast response, and long-term stability, making it ideal for compressed air systems, HVAC monitoring, and industrial drying processes.
-The sensor’s condensation-resistant design ensures accurate readings even under high humidity or fluctuating ambient conditions.
Key Highlights:
*Operating Temperature: −40 ~ +60 °C
*Dew Point Range: −60 ~ +60 °C (−76 ~ +140 °F)
*Accuracy: ±2 °C Td (±3.6 °F)
*Output Options: RS-485 (Modbus-RTU) + 4–20 mA / 0–5 V / 0–10 V
*Condensation Resistance: Sensor remains dry and stable under high humidity
*Wide Power Supply: 10 – 28 V DC with polarity protection
*Strong Compatibility: Standard Modbus protocol for seamless system integration
Idealny dla:
Compressed Air | HVAC | Industrial Drying | Environmental Control
📩 Contact us to customize your HG602-D dew point monitoring solution today.
SPECYFIKACJA
| Model | Wyjście (T: Temperatura, H: Wilgotność, DP: Punkt rosy) | Zakres punktu rosy | Zakres temperatur | Zakres wilgotności | Odporność na kondensację |
|---|---|---|---|---|---|
| HG602-D | T + H + DP (odczyt jednocześnie) + (4 - 20 mA), T - H - DP (wybór 1 z 3) | -60 ~ +60°C (można ustawić w zakresie) | -40 ~ 60°C | 0 ~ 100%RH | Y |
🔹Features
- Operating temperature: up to +60 °C, suitable for medium-temperature environments
- Dew point measurement range: −60 ~ +60 °C (−76 ~ +140 °F)
- High accuracy: ±2 °C Td (±3.6 °F) for precise process control
- Excellent long-term stability and reliable signal performance
- Szybka reakcja for dynamic humidity and dew point changes
- Multiple dual-output configurations:
• Modbus RS-485 + 4–20 mA
• Modbus RS-485 + 0–5 V
• Modbus RS-485 + 0–10 V - Condensation-resistant sensor design — stays dry in high humidity with minimal lag
- Strong compatibility: Standard Modbus-RTU protocol for easy connection with PLC, DCS, and SCADA systems
- Power protection: Wide 10 – 28 V DC input with reverse polarity protection
- Durable sintered stainless steel filter head (60 µm standard, OEM pore size optional)
Dane techniczne
| Kategoria | Specyfikacja techniczna i funkcje |
|---|---|
| Zasilanie | DC 10V ~ 30V (zalecane zasilanie 12V) |
| Rozpraszanie mocy | <0.1W |
| Zakres punktu rosy | -60 ~ +60°C (można ustawić w zakresie) |
| Work Temperature range | -40 ~ +60°C |
| Zakres wilgotności | 0 ~ 100%RH (zalecane <90%RH) |
| Wyjście analogowe | Temperatura, wilgotność, punkt rosy (wybierz 1 z 3) |
| Wyjście RS485 | Temperatura, wilgotność, punkt rosy (odczytywane jednocześnie) |
| Typowa dokładność (20°C, 50%RH, jedna standardowa atmosfera) | |
| Temperatura | ±0.1°C |
| Punkt rosy | ±2 °C (±3.6℉)Td Accuracy (Dew Point) |
| Wilgotność | ±1,5%RH |
| Rozdzielczość wyjścia cyfrowego | Możliwość wyboru 0,01°C / 0,1°C<br>0,01%RH / 0,1%RH do wyboru |
| Szybkość transmisji komunikacji | 1200, 2400, 4800, 9600, 19200, 115200 z możliwością ustawienia, domyślnie 9600 pbs |
| Wyjście (jednocześnie) | 1 trasa: 4 ~ 20mA (RL≤500Ω)<br>1 trasa: RS485 Modbus-RTU Port komunikacyjny Modbus: RTU,9.6k/19.2k/38.4k/57.6k/115.2kBaud |
| Częstotliwość pozyskiwania | Najszybsza odpowiedź 1s, inne mogą być ustawione przez PLC |
| Format bajtowy | 8 bitów danych, 1 bit stopu, brak kontroli |
| Ciśnienie | 16 bar |
Numer zamówienia :
| Model | Wyjście sygnału | Wartość wyjściowa | Zakres punktu rosy | Zakres temperatur |
|---|---|---|---|---|
| HG602-D4 | 4-20 mA + RS485 | Punkt rosy | -60 do 60 °C | -40 to60 °C |
| HG602-D5 | 0-5 V + RS 485 | Punkt rosy | -60 do 60 °C | -40 to 60 °C |
| HG602-D1 | 0-10 V + RS 485 | Punkt rosy | -60 do 60 °C | -40 to 60 °C |
Często używany w
- Systemy sprężonego powietrza
- Monitorowanie gazu ziemnego
- Systemy HVAC
- Produkcja farmaceutyczna
- Przetwarzanie żywności i napojów
- Produkcja gazu przemysłowego
- Produkcja półprzewodników
- Przetwarzanie chemiczne
- Przemysł naftowy i gazowy
Powiązane produkty
Jest to galeria prezentująca obrazy z ostatnich postów społecznościowych.
Blogi
Why Standard Sensors Fail in High-Temperature Humidity Measurement ?
Why Standard Humidity Sensors Fail in High-Temperature Environments Quick Summary Standard humidity sensors are mainly designed for ambient or moderate industrial conditions. Under sustained high temperatures, steam, contaminants, and repeated thermal cycling, they can suffer from material degradation, measurement drift, condensation damage, and shortened service life. This article explains the most common failure mechanisms and
Why High-Temperature and Humidity Transmitters Are Critical for Industrial Drying Processes
How to Monitor Temperature and Humidity in High-Temperature Industrial Drying Processes Quick Summary Industrial drying processes used in pharmaceuticals, food production, chemicals, ceramics, and materials manufacturing require precise control of temperature and humidity. Even small deviations can cause product defects, excessive energy consumption, longer drying cycles, or equipment damage. This guide explains why high-temperature drying
200℃ High-Temperature Humidity Transmitter for Industrial Drying Ovens HG808-T
High-Temperature Humidity Transmitter for 200℃ Industrial Drying Ovens-HG808-T In many manufacturing processes, drying is more than just a step — it’s a decisive factor that directly affects product quality, production efficiency, and energy consumption. Whether you’re drying ceramics, powder materials, food ingredients, coatings, lithium battery materials, or industrial components, temperature and moisture inside the drying
Optymalizacja osuszaczy dzięki zaawansowanemu monitorowaniu temperatury i wilgotności
Effective moisture management is essential in facilities where materials, equipment, and processes depend on controlled environmental conditions. While dehumidifiers play a central role, their performance—and efficiency—largely depends on accurate temperature and humidity monitoring. With advanced transmitters providing continuous, real-time environmental data, dehumidifiers can operate intelligently rather than blindly, ensuring consistent protection and optimal operating costs.
Jak działają przetworniki wilgotności i temperatury?
In short, Humidity and temperature transmitters measure and send environmental data to control systems. They are widely used in HVAC, pharmaceuticals, food processing, and cleanrooms where precise conditions are critical. Sensing: Built-in humidity and temperature sensors detect moisture and heat changes. Signal Conversion: The device converts raw signals into standard outputs like 4–20 mA or
Dlaczego mierniki punktu rosy osuszaczy mają kluczowe znaczenie dla systemów sprężonego powietrza?
Why Are Dryer Dew Point Meters Critical for Compressed Air Systems? Maybe You always battle hidden moisture in compressed air that can cause corrosion, freezing, and product defects. By installing dew point meters, you detect and stop moisture issues before equipment fails. You can monitor dew point to prevent condensation and protect assets. The HENGKO
Dlaczego jedna strefa biurowa jest zbyt wilgotna i jak można to naprawić za pomocą przetwornika wilgotności?
Why One Office Zone is Too Humid & How a Humidity Transmitter Fixes It Persistent humidity in one office zone can disrupt comfort, increase mold risk, and hurt productivity. Even with your HVAC system running, one area may stay damp due to hidden airflow issues or localized moisture sources. A humidity transmitter acts like a
Dlaczego warto monitorować temperaturę i wilgotność w osuszaczach chłodniczych?
Introduction Compressed air is often referred to as the “fourth utility” in modern industry, alongside electricity, water, and gas. Yet, one of the most common issues facing compressed air systems is moisture. When untreated, moisture can lead to corrosion, blocked pipelines, damaged pneumatic equipment, and compromised product quality. To address this, refrigerated air dryers—commonly known
Ochrona produkcji półprzewodników za pomocą precyzyjnych urządzeń monitorujących temperaturę i wilgotność
1. Introduction The semiconductor industry operates under some of the most stringent environmental conditions of any manufacturing sector. As devices shrink to the nanoscale and production processes grow increasingly complex, maintaining precise control over environmental parameters—particularly temperature and humidity—has become critical to ensuring consistent quality and yield. Even slight fluctuations in temperature or humidity can
Jak przetworniki temperatury i wilgotności zapewniają precyzję w komorach?
Introduction In the world of environmental simulation and reliability testing, constant temperature and humidity chambers are indispensable tools across a wide range of industries—from electronics and pharmaceuticals to materials science and aerospace. These chambers are engineered to maintain a precisely controlled climate, ensuring stable temperature and relative humidity (RH) for extended testing cycles. But what