Stable and Accurate Dew Point Monitoring for Industrial and Environmental Applications
The HG602-D is a compact, high-reliability transmitter for dew point, temperature, and humidity measurement in environments up to 60 °C (140 °F).
-It delivers ±2 °C Td accuracy, fast response, and long-term stability, making it ideal for compressed air systems, HVAC monitoring, and industrial drying processes.
-The sensor’s condensation-resistant design ensures accurate readings even under high humidity or fluctuating ambient conditions.
Key Highlights:
*Operating Temperature: −40 ~ +60 °C
*Dew Point Range: −60 ~ +60 °C (−76 ~ +140 °F)
*Accuracy: ±2 °C Td (±3.6 °F)
*Output Options: RS-485 (Modbus-RTU) + 4–20 mA / 0–5 V / 0–10 V
*Condensation Resistance: Sensor remains dry and stable under high humidity
*Wide Power Supply: 10 – 28 V DC with polarity protection
*Strong Compatibility: Standard Modbus protocol for seamless system integration
Ideal for:
Compressed Air | HVAC | Industrial Drying | Environmental Control
📩 Contact us to customize your HG602-D dew point monitoring solution today.
| Modell | Kimenet (T: hőmérséklet, H: páratartalom, DP: harmatpont) | Harmatpont tartomány | Hőmérséklet tartomány | Páratartalom tartomány | Ellenáll a kondenzációnak |
|---|---|---|---|---|---|
| HG602- D | T + H + DP (egyidejűleg olvasható) + (4-20 mA), T - H - DP (válasszon 1-et a 3 közül) | -60 ~ +60°C (a tartományon belül állítható) | -40 ~ 60°C | 0 ~ 100%RH | Y |
🔹Features
| Kategória | Műszaki specifikációk és jellemzők |
|---|---|
| Tápegység | DC 10V ~ 30V (12V-os tápegység ajánlott) |
| Teljesítményleadás | <0.1W |
| Harmatpont tartomány | -60 ~ +60°C (a tartományon belül állítható) |
| Work Temperature range | -40 ~ +60°C |
| Páratartalom tartomány | 0 ~ 100%RH ( <90%RH ajánlott) |
| Analóg kimenet | Hőmérséklet, páratartalom, harmatpont (válasszon 1-et a 3 közül) |
| RS485 kimenet | Hőmérséklet, páratartalom, harmatpont (egyidejűleg olvasható) |
| Tipikus pontosság (20°C, 50%RH, Egy szabványos légkör) | |
| Hőmérséklet | ±0.1°C |
| Harmatpont | ±2 °C (±3.6℉)Td Accuracy (Dew Point) |
| Páratartalom | ±1,5%RH |
| Digitális kimeneti felbontás | 0,01°C / 0,1°C választható<br>0,01%RH / 0,1%RH választható |
| Kommunikációs baud-ráta | 1200, 2400, 4800, 9600, 19200, 115200 beállítható, alapértelmezett 9600 pbs |
| Kimenet (egyidejűleg) | 1 útvonal: (RL≤500Ω)<br>1 útvonal: RS485 Modbus-RTU Modbus kommunikációs port: RTU,9.6k/19.2k/38.4k/57.6k/115.2kBaud |
| Gyűjtési gyakoriság | A leggyorsabb 1s válasz, a többi beállítható a PLC által |
| Byte formátum | 8 adatbit, 1 stopbit, ellenőrzés nélkül |
| Nyomás | 16 bar |
Rendelési szám :
| Modell | Jel kimenet | Kimeneti érték | Harmatpont tartomány | Hőmérséklet-tartomány |
|---|---|---|---|---|
| HG602-D4 | 4-20 mA + RS485 | Harmatpont | -60 és 60 °C között | -40 to60 °C |
| HG602-D5 | 0-5v + RS 485 | Harmatpont | -60 és 60 °C között | -40 to 60 °C |
| HG602-D1 | 0-10v + RS 485 | Harmatpont | -60 és 60 °C között | -40 to 60 °C |
Ez egy galéria a legutóbbi közösségi bejegyzéseidből származó képek bemutatására.
Why Standard Humidity Sensors Fail in High-Temperature Environments Quick Summary Standard humidity sensors are mainly designed for ambient or moderate industrial conditions. Under sustained high
How to Monitor Temperature and Humidity in High-Temperature Industrial Drying Processes Quick Summary Industrial drying processes used in pharmaceuticals, food production, chemicals, ceramics, and materials
High-Temperature Humidity Transmitter for 200℃ Industrial Drying Ovens-HG808-T In many manufacturing processes, drying is more than just a step — it’s a decisive factor that
Effective moisture management is essential in facilities where materials, equipment, and processes depend on controlled environmental conditions. While dehumidifiers play a central role, their performance—and
Röviden, a páratartalom- és hőmérséklet-jeladók mérik és küldik a környezeti adatokat a vezérlőrendszereknek. Széles körben használják őket a HVAC, a gyógyszeripar, az élelmiszer-feldolgozás és a tisztaterek területén.
Miért kritikusak a szárító harmatpontmérők a sűrített levegős rendszereknél? Talán Mindig a sűrített levegőben lévő rejtett nedvességgel küzd, amely korróziót, fagyást okozhat,
Miért túl párás az egyik irodai zóna és hogyan javítja meg egy páratartalom-jeladó a helyzetet A tartós páratartalom egy irodai zónában megzavarhatja a kényelmet, növelheti a penészesedést.
Bevezetés A sűrített levegőt gyakran nevezik a modern ipar "negyedik közművének" a villamos energia, a víz és a gáz mellett. Mégis, az egyik leggyakoribb
1. Bevezetés A félvezetőipar a legszigorúbb környezeti feltételek mellett működik a gyártóiparban. Ahogy az eszközök a nanoméretűre zsugorodnak és a
Bevezetés A környezeti szimuláció és a megbízhatósági tesztek világában az állandó hőmérsékletű és páratartalmú kamrák nélkülözhetetlen eszközök az iparágak széles körében - az elektronikai
WhatsApp minket