Stable and Accurate Dew Point Monitoring for Industrial and Environmental Applications
The HG602-D is a compact, high-reliability transmitter for dew point, temperature, and humidity measurement in environments up to 60 °C (140 °F).
-It delivers ±2 °C Td accuracy, fast response, and long-term stability, making it ideal for compressed air systems, HVAC monitoring, and industrial drying processes.
-The sensor’s condensation-resistant design ensures accurate readings even under high humidity or fluctuating ambient conditions.
Key Highlights:
*Operating Temperature: −40 ~ +60 °C
*Dew Point Range: −60 ~ +60 °C (−76 ~ +140 °F)
*Accuracy: ±2 °C Td (±3.6 °F)
*Output Options: RS-485 (Modbus-RTU) + 4–20 mA / 0–5 V / 0–10 V
*Condensation Resistance: Sensor remains dry and stable under high humidity
*Wide Power Supply: 10 – 28 V DC with polarity protection
*Strong Compatibility: Standard Modbus protocol for seamless system integration
Idealisk för:
Compressed Air | HVAC | Industrial Drying | Environmental Control
📩 Contact us to customize your HG602-D dew point monitoring solution today.
| Modell | Utgång (T: Temperatur, H: Luftfuktighet, DP: Daggpunkt) | Daggpunktsintervall | Temperaturområde | Område för luftfuktighet | Motstår kondensation |
|---|---|---|---|---|---|
| HG602- D | T + H + DP (läs samtidigt) + (4 - 20 mA), T - H - DP (välj 1 av 3) | -60 ~ +60°C (kan ställas in inom intervallet) | -40 ~ 60°C | 0 ~ 100%RH | Y |
🔹Features
| Kategori | Tekniska specifikationer och funktioner |
|---|---|
| Strömförsörjning | DC 10V ~ 30V (12V strömförsörjning rekommenderas) |
| Effektförlust | <0.1W |
| Daggpunktsintervall | -60 ~ +60°C (kan ställas in inom intervallet) |
| Work Temperature range | -40 ~ +60°C |
| Område för luftfuktighet | 0 ~ 100%RH (<90%RH rekommenderas) |
| Analog utgång | Temperatur, luftfuktighet, daggpunkt (välj 1 av 3) |
| RS485-utgång | Temperatur, luftfuktighet, daggpunkt (avläses samtidigt) |
| Typisk noggrannhet (20°C, 50%RH, en standardatmosfär) | |
| Temperatur | ±0.1°C |
| Daggpunkt | ±2 °C (±3.6℉)Td Accuracy (Dew Point) |
| Luftfuktighet | ±1,5%RH |
| Digital utgångsupplösning | 0,01°C / 0,1°C valbar<br>0,01%RH / 0,1%RH valbar |
| Kommunikationens baudhastighet | 1200, 2400, 4800, 9600, 19200, 115200 inställbar, standard 9600 pbs |
| Utgång (samtidigt) | 1 rutt: 4 ~ 20 mA (RL≤500Ω)<br>1 rutt: RS485 Modbus-RTU Modbus-kommunikationsport: RTU,9.6k/19.2k/38.4k/57.6k/115.2kBaud |
| Förvärvsfrekvens | Den snabbaste responsen är 1s, övriga kan ställas in av PLC |
| Byteformat | 8 databitar, 1 stoppbit, ingen kontroll |
| Tryck | 16 bar |
Beställningsnummer :
| Modell | Signalutgång | Utgångsvärde | Daggpunktsintervall | Temp-intervall |
|---|---|---|---|---|
| HG602-D4 | 4-20 mA + RS485 | Daggpunkt | -60 till 60 °C | -40 to60 °C |
| HG602-D5 | 0-5v + RS 485 | Daggpunkt | -60 till 60 °C | -40 to 60 °C |
| HG602-D1 | 0-10v + RS 485 | Daggpunkt | -60 till 60 °C | -40 to 60 °C |
Detta är ett galleri för att visa upp bilder från dina senaste sociala inlägg
Humidity measurement is relatively straightforward at ambient conditions. Most standard sensors perform adequately in offices, warehouses, and general HVAC environments. However, once temperatures rise above
Industrial drying processes—used in pharmaceuticals, food, chemicals, and materials—demand precise control of temperature and humidity. Deviations can lead to product defects, energy waste, or even
High-Temperature Humidity Transmitter for 200℃ Industrial Drying Ovens-HG808-T In many manufacturing processes, drying is more than just a step — it’s a decisive factor that
Effective moisture management is essential in facilities where materials, equipment, and processes depend on controlled environmental conditions. While dehumidifiers play a central role, their performance—and
Kortfattat mäter och skickar transmitters för luftfuktighet och temperatur miljödata till styrsystem. De används ofta inom HVAC, läkemedel, livsmedelsbearbetning och renrum.
Varför är daggpunktsmätare för torktumlare kritiska för tryckluftssystem? Kanske Du kämpar alltid mot dold fukt i tryckluft som kan orsaka korrosion och frysning,
Varför en kontorszon är för fuktig och hur en luftfuktighetssändare löser det Ihållande luftfuktighet i en kontorszon kan störa komforten, öka mögel
Inledning Tryckluft kallas ofta för det "fjärde verktyget" i modern industri, vid sidan av el, vatten och gas. Ändå är en av de vanligaste
1. Inledning Halvledarindustrin verkar under några av de strängaste miljöförhållandena inom någon tillverkningssektor. I takt med att enheter krymper till nanoskalan och
Introduktion I en värld av miljösimulering och tillförlitlighetstestning är kammare med konstant temperatur och luftfuktighet oumbärliga verktyg inom ett brett spektrum av branscher - från elektronik