Dew Point Transmitter Sensor - HG602-D 

αρνητικό εικονίδιο λειτουργίας πομπού σημείου δρόσου 60 ℃ από την HENGKO

HG602-D Dew Point Transmitter (Up to 60 °C) for Industrial Air Compressors

Stable and Accurate Dew Point Monitoring for Industrial and Environmental Applications

The HG602-D is a compact, high-reliability transmitter for dew point, temperature, and humidity measurement in environments up to 60 °C (140 °F).
-It delivers ±2 °C Td accuracy, fast response, and long-term stability, making it ideal for compressed air systems, HVAC monitoring, and industrial drying processes.
-The sensor’s condensation-resistant design ensures accurate readings even under high humidity or fluctuating ambient conditions.

Key Highlights:
*Operating Temperature: −40 ~ +60 °C
*Dew Point Range: −60 ~ +60 °C (−76 ~ +140 °F)
*Accuracy: ±2 °C Td (±3.6 °F)
*Output Options: RS-485 (Modbus-RTU) + 4–20 mA / 0–5 V / 0–10 V
*Condensation Resistance: Sensor remains dry and stable under high humidity
*Wide Power Supply: 10 – 28 V DC with polarity protection
*Strong Compatibility: Standard Modbus protocol for seamless system integration

Ιδανικό για:
Compressed Air | HVAC | Industrial Drying | Environmental Control

📩 Contact us to customize your HG602-D dew point monitoring solution today.

ΠΡΟΔΙΑΓΡΑΦΕΣ

ΜοντέλοΈξοδος (T: Θερμοκρασία, H: Υγρασία, DP: Σημείο δρόσου)Εύρος σημείου δρόσουΕύρος θερμοκρασίαςΕύρος υγρασίαςΑντέχει στη συμπύκνωση
HG602- D             T + H + DP (read simultaneously) + (4 – 20 mA), T – H – DP          (choose 1 from 3)                         -60 ~ +60°C (can be set within the range)-40 ~ 60°C0 ~ 100%RH Y

🔹Features

  • Operating temperature: up to +60 °C, suitable for medium-temperature environments
  • Dew point measurement range: −60 ~ +60 °C (−76 ~ +140 °F)
  • High accuracy: ±2 °C Td (±3.6 °F) for precise process control
  • Excellent long-term stability and reliable signal performance
  • Γρήγορη ανταπόκριση for dynamic humidity and dew point changes
  • Multiple dual-output configurations:
     • Modbus RS-485 + 4–20 mA
     • Modbus RS-485 + 0–5 V
     • Modbus RS-485 + 0–10 V
  • Condensation-resistant sensor design — stays dry in high humidity with minimal lag
  • Ισχυρή συμβατότητα: Standard Modbus-RTU protocol for easy connection with PLC, DCS, and SCADA systems
  • Προστασία ισχύος: Wide 10 – 28 V DC input with reverse polarity protection
  • Durable sintered stainless steel filter head (60 µm standard, OEM pore size optional)

Technical data

ΚατηγορίαΤεχνικές προδιαγραφές και χαρακτηριστικά
Παροχή ρεύματοςDC 10V ~ 30V (συνιστάται τροφοδοτικό 12V)
Διασπορά ισχύος<0.1W
Εύρος σημείου δρόσου-60 ~ +60°C (can be set within the range)
Work Temperature range-40 ~ +60°C 
Εύρος υγρασίας0 ~ 100%RH ( <90%RH συνιστάται)
Αναλογική έξοδοςΘερμοκρασία, Υγρασία, Σημείο δρόσου (επιλέξτε 1 από 3)
Έξοδος RS485Θερμοκρασία, Υγρασία, Σημείο δρόσου (ταυτόχρονη ανάγνωση)
Τυπική ακρίβεια (20°C, 50%RH, Μία τυπική ατμόσφαιρα) 
Θερμοκρασία±0.1°C
Σημείο δρόσου±2 °C (±3.6℉)Td Accuracy (Dew Point)
Υγρασία±1,5%RH
Ψηφιακή ανάλυση εξόδουΕπιλογή 0,01°C / 0,1°C<br>Επιλογή 0,01%RH / 0,1%RH
Ρυθμός baud επικοινωνίας1200, 2400, 4800, 9600, 19200, 115200 ρυθμιζόμενα, προεπιλογή 9600 pbs
Έξοδος (ταυτόχρονα)

1 διαδρομή: (RL≤500Ω)<br>1 διαδρομή: RS485 Modbus-RTU

Θύρα επικοινωνίας Modbus: RTU,9.6k/19.2k/38.4k/57.6k/115.2kBaud

Συχνότητα λήψηςΗ ταχύτερη απόκριση 1s, οι άλλες μπορούν να ρυθμιστούν από το PLC
Μορφή byte8 bits δεδομένων, 1 stop bit, χωρίς έλεγχο
Πίεση16 bar

Order Number :

ΜοντέλοSignal OutputOutput ValueΕύρος σημείου δρόσουTemp Range
HG602-D44-20 mA + RS485   Σημείο δρόσου-60 to 60 °C-40 to60 °C
HG602-D50-5v + RS 485 Σημείο δρόσου-60 to 60 °C-40 to 60 °C
HG602-D10-10v + RS 485 Σημείο δρόσου-60 to 60 °C-40 to 60 °C

Often used in

Blogs

Why Standard Sensors Fail in High-Temperature Humidity Measurement ?

Why Standard Humidity Sensors Fail in High-Temperature Environments Quick Summary Standard humidity sensors are mainly designed for ambient or moderate industrial conditions. Under sustained high temperatures, steam, contaminants, and repeated thermal cycling, they can suffer from material degradation, measurement drift, condensation damage, and shortened service life. This article explains the most common failure mechanisms and

Διαβάστε περισσότερα "

Why High-Temperature and Humidity Transmitters Are Critical for Industrial Drying Processes

How to Monitor Temperature and Humidity in High-Temperature Industrial Drying Processes Quick Summary Industrial drying processes used in pharmaceuticals, food production, chemicals, ceramics, and materials manufacturing require precise control of temperature and humidity. Even small deviations can cause product defects, excessive energy consumption, longer drying cycles, or equipment damage. This guide explains why high-temperature drying

Διαβάστε περισσότερα "

200℃ High-Temperature Humidity Transmitter for Industrial Drying Ovens HG808-T

High-Temperature Humidity Transmitter for 200℃ Industrial Drying Ovens-HG808-T In many manufacturing processes, drying is more than just a step — it’s a decisive factor that directly affects product quality, production efficiency, and energy consumption. Whether you’re drying ceramics, powder materials, food ingredients, coatings, lithium battery materials, or industrial components, temperature and moisture inside the drying

Διαβάστε περισσότερα "

Βελτιστοποίηση των αφυγραντήρων με προηγμένη παρακολούθηση θερμοκρασίας και υγρασίας

Effective moisture management is essential in facilities where materials, equipment, and processes depend on controlled environmental conditions. While dehumidifiers play a central role, their performance—and efficiency—largely depends on accurate temperature and humidity monitoring. With advanced transmitters providing continuous, real-time environmental data, dehumidifiers can operate intelligently rather than blindly, ensuring consistent protection and optimal operating costs.

Διαβάστε περισσότερα "

Πώς λειτουργούν οι πομποί υγρασίας και θερμοκρασίας;

In short, Humidity and temperature transmitters measure and send environmental data to control systems. They are widely used in HVAC, pharmaceuticals, food processing, and cleanrooms where precise conditions are critical. Sensing: Built-in humidity and temperature sensors detect moisture and heat changes. Signal Conversion: The device converts raw signals into standard outputs like 4–20 mA or

Διαβάστε περισσότερα "

Γιατί οι μετρητές σημείου δρόσου στεγνωτήρα είναι κρίσιμοι για τα συστήματα πεπιεσμένου αέρα;

Why Are Dryer Dew Point Meters Critical for Compressed Air Systems? Maybe You always battle hidden moisture in compressed air that can cause corrosion, freezing, and product defects. By installing dew point meters, you detect and stop moisture issues before equipment fails. You can monitor dew point to prevent condensation and protect assets. The HENGKO

Διαβάστε περισσότερα "

Γιατί μια ζώνη γραφείου είναι πολύ υγρή & πώς ένας πομπός υγρασίας το διορθώνει;

Why One Office Zone is Too Humid & How a Humidity Transmitter Fixes It Persistent humidity in one office zone can disrupt comfort, increase mold risk, and hurt productivity. Even with your HVAC system running, one area may stay damp due to hidden airflow issues or localized moisture sources. A humidity transmitter acts like a

Διαβάστε περισσότερα "

Γιατί να παρακολουθείτε τη θερμοκρασία και την υγρασία σε στεγνωτήρια ψυχόμενου αέρα;

Introduction Compressed air is often referred to as the “fourth utility” in modern industry, alongside electricity, water, and gas. Yet, one of the most common issues facing compressed air systems is moisture. When untreated, moisture can lead to corrosion, blocked pipelines, damaged pneumatic equipment, and compromised product quality. To address this, refrigerated air dryers—commonly known

Διαβάστε περισσότερα "

Διασφάλιση της παραγωγής ημιαγωγών με συσκευές παρακολούθησης θερμοκρασίας και υγρασίας ακριβείας

1. Introduction The semiconductor industry operates under some of the most stringent environmental conditions of any manufacturing sector. As devices shrink to the nanoscale and production processes grow increasingly complex, maintaining precise control over environmental parameters—particularly temperature and humidity—has become critical to ensuring consistent quality and yield. Even slight fluctuations in temperature or humidity can

Διαβάστε περισσότερα "

Πώς οι πομποί θερμοκρασίας και υγρασίας εξασφαλίζουν ακρίβεια στους θαλάμους

Introduction In the world of environmental simulation and reliability testing, constant temperature and humidity chambers are indispensable tools across a wide range of industries—from electronics and pharmaceuticals to materials science and aerospace. These chambers are engineered to maintain a precisely controlled climate, ensuring stable temperature and relative humidity (RH) for extended testing cycles. But what

Διαβάστε περισσότερα "

Επικοινωνήστε μαζί μας