HG808 Harsh-Environment Temperature, Humidity & Dew Point Transmitters
The HG808 Series by HENGKO delivers accurate, stable, long-term measurements of temperature, humidity, and dew point in extreme heat, continuous high humidity, corrosive gases, and dry-gas processes.
Up to +200°C HG808-T, short-term
0-100% RH Temperature & humidity models
−20 to +100°C Td HG808-A dew point range
±1,5% RH HG808-C humidity accuracy
Manufacturer
OEM / factory
Harsh industrial environments
2-year warranty on all products
Built for the conditions that cause ordinary transmitters to fail
Harsh-process monitoring usually breaks down in one of four ways: heat beyond the sensing element, continuous high humidity or condensation, chemical attack, or a dry-gas duty where dew point is the right metric—not relative humidity. The HG808 series is grouped to those conditions.
High temperature
In furnaces, kilns, and high-temperature ovens, a standard humidity element is out of range. HG808-T uses a high-temperature sensing element rated up to 200°C (recommended +85…+180°C; short-term +200°C) with a 316L stainless steel probe.
Start with HG808-T
Continuous high humidity
Long-term monitoring in moisture-intensive processes needs a transmitter designed for continuous high humidity, not a short peak. HG808-H is specified for that duty, with a recommended operating range of 40–95% RH and a maximum recommended 98% RH.
Start with HG808-H
Corrosive exposure
Acids, alkalis, disinfectants, and selected chemical gases attack ordinary sensors and housings. HG808-F uses a corrosion-resistant humidity sensor in a stainless steel IP65 housing; HG808-G is the corrosion-resistant dew-point option for selected chemical gas streams.
Dry gas and dew point
When the process is dry, relative humidity is a poor control variable. Use dew point instead: HG808-A for high-temperature drying (−20 to +100°C Td), HG808-D for industrial dry gas and compressed air (−60 to +90°C Td), and HG808-G for low dew point in selected chemical gases (−60 to +20°C Td).
Choose the right HG808 in three steps
First pick temperature & humidity or dew point, then match the operating condition to a model. Probe type and installation fitting are configuration options — they do not change the recommended model. Series outputs include RS485/Modbus-RTU, 4–20mA, 0–5V and 0–10V; there is no verified per-model I/O matrix on this page.
Probe type — official catalogue codes. After a model is recommended, only the applicable probes for that model are shown.
A = 316L stainless steel sintered sensor housing · B = 316L stainless steel grid sensor housing
Installation fitting
Accessory
The live page labels one thread option “NTP1/2”; that is shown here as NPT1/2.
Recommended model
HG808-T High-Temperature Transmitter
Designed for continuous operation in high-temperature environments. The sensing element is rated up to 200°C (recommended +85…+180°C; short-term +200°C) with a 316L stainless steel probe.
- Temperature: -40…+200°C (rec. +85…+180; short-term +200)
- Humidity / dew point: 0-100% RH
- Precisión: Temp ±0.3°C (@85°C); Humidity ±2.5% RH (@85°C, 10–90% RH)
Recommended model
HG808-H High-Humidity Transmitter
Designed for long-term monitoring under consistently high humidity, with a robust cast aluminum housing, stainless steel sensor assembly, and enhanced corrosion resistance. Recommended operating humidity is 40–95% RH, with a maximum recommended 98% RH.
- Temperature: -40 to +100°C
- Humidity / dew point: 0-100% RH
- Precisión: Temp ±0.1°C (@23°C); Humidity ±2% RH (@23°C, 40–95% RH)
Recommended model
HG808-C High-Precision Transmitter
High-precision temperature and humidity measurement with advanced sensor calibration, a wide measurement range, and excellent long-term stability.
- Temperature: -50 to +150°C
- Humidity / dew point: 0-100% RH
- Precisión: Temp ±0.1°C (@23°C); Humidity ±1.5% RH (@23°C, 10–90% RH)
Recommended model
HG808-F Corrosion-Resistant Transmitter New
Built for environmental monitoring in chemically demanding conditions, with a corrosion-resistant sensor, stainless steel housing, IP65 protection, and a modular probe. Anti-acid, alkali and disinfectant design.
- Temperature: -40 to +120°C
- Humidity / dew point: 0-100% RH
- Precisión: Temp ±0.2°C (@23°C); Humidity ±2.5% RH (@23°C, 10–90% RH)
Recommended model
HG808-A High-Temperature Dew Point Transmitter
Designed for moisture monitoring in elevated-temperature processes, with high-temperature dew point sensing, a cast aluminum housing, and a stainless steel sensor assembly. Datasheet dew point range is -20 to +100°C Td, with accuracy ±3°C Td.
- Temperature: -80 to +180°C
- Humidity / dew point: Dew point -20 to +100°C Td
- Precisión: Dew point ±3°C Td
Recommended model
HG808-D Industrial Dew Point Transmitter
Suitable for general industrial dew point measurement in compressed air, dry gas pipelines, and glove boxes. Dew point range -60 to +90°C Td, accuracy ±2°C Td. The series selection guide also lists 4–20 mA / RS485 output for HG808-D.
- Temperature: -40 to +90°C
- Humidity / dew point: Dew point -60 to +90°C Td
- Precisión: Dew point ±2°C Td
Recommended model
HG808-G Transmisor de punto de rocío resistente a la corrosión
Designed for low dew point measurement in selected chemical gas environments, with stable moisture measurement in dry gases and an enhanced corrosion-resistant design. Dew point range -60 to +20°C Td, accuracy ±3°C Td.
- Temperature: -20 to +60°C
- Humidity / dew point: Dew point -60 to +20°C Td
- Precisión: Dew point ±3°C Td
Seven models, grouped by what they measure
Temperature & humidity models cover high heat, continuous high humidity, high precision, and corrosive conditions. Dew point models cover high-temperature, industrial dry gas, and corrosive or low dew-point use. Across the series, available outputs include RS485/Modbus-RTU, 4–20mA, 0–5V and 0–10V.
Temperature & humidity
HG808-T
High-Temperature Transmitter
- Continuous operation in high-temperature environments
- Sensing element up to 200°C (rec. +85…+180°C; short-term +200°C)
- 316L stainless steel probe
HG808-H
High-Humidity Transmitter
- Long-term monitoring under continuous high humidity
- Recommended 40–95% RH (max 98% RH)
- Cast aluminum housing with stainless steel sensor
HG808-C
High-Precision Transmitter
- High-precision temperature and humidity measurement
- Precisión ±0.1°C / ±1,5% RH
- Wide range: -50 to +150°C, 0-100% RH
HG808-F New
Corrosion-Resistant Transmitter
- Corrosion-resistant sensor (anti-acid, alkali, disinfectant)
- Stainless steel housing, IP65
- Modular probe
Punto de rocío
HG808-A
High-Temperature Dew Point Transmitter
- Moisture monitoring for elevated-temperature processes
- Punto de rocío -20 to +100°C Td, ±3°C Td
- Cast aluminum housing with stainless steel sensor
HG808-D
Industrial Dew Point Transmitter
- Industrial dew-point use in compressed air, dry gas, and glove boxes
- Range -60 to +90°C Td, ±2°C Td
- 4–20 mA / RS485 output
HG808-G
Corrosion-Resistant Dew Point Transmitter
- Low dew point measurement in selected chemical gas environments
- Range -60 to +20°C Td, ±3°C Td
- Enhanced corrosion-resistant design
Compare the HG808 models
Figures below are taken from the live series datasheet table. Filter by group, or jump here from the selector to highlight a recommended model. On a phone, swipe the table sideways.
| Modelo | Temperatura | Humidity / Dew Point Range |
Measurement Accuracy | Características principales | Typical Applications | CTA |
|---|---|---|---|---|---|---|
| -40…+200°C (rec. +85…+180; short-term +200) | 0-100% RH | Temp ±0.3°C (@85°C); Humidity ±2.5% RH (@85°C, 10–90% RH) |
|
|
InquireView product | |
| -40 to +100°C | 0-100% RH | Temp ±0.1°C (@23°C); Humidity ±2% RH (@23°C, 40–95% RH) |
|
|
InquireView product | |
| -50 to +150°C | 0-100% RH | Temp ±0.1°C (@23°C); Humidity ±1.5% RH (@23°C, 10–90% RH) |
|
|
InquireView product | |
| -40 to +120°C | 0-100% RH | Temp ±0.2°C (@23°C); Humidity ±2.5% RH (@23°C, 10–90% RH) |
|
|
InquireLearn more | |
| -80 to +180°C | Dew point -20 to +100°C Td | Dew point ±3°C Td |
|
|
InquireView product | |
| -40 to +90°C | Dew point -60 to +90°C Td | Dew point ±2°C Td |
|
|
InquireView product | |
| -20 to +60°C | Dew point -60 to +20°C Td | Dew point ±3°C Td |
|
|
InquireView product |
Temperature ranges, humidity ranges and dew point ranges refer to different measurement parameters. Accuracy values apply under the specified reference conditions. Actual performance may vary with installation and operating conditions.
Humidity probes and installation fittings
The HG808 series is offered with nine official probe styles from the catalogue: 0A#, 0B#, 3A#, 3B#, 5A#, 6A#, 6B#, 8A# and 8B#. A = 316L stainless steel sintered sensor housing; B = 316L stainless steel grid sensor housing. Applicable styles vary by model — the selector shows only the probes listed for the recommended model.
Probe installation
Fitting options: M20 hexagonal thread, G1/2, NPT1/2 (labelled NTP1/2 on the live page), M27 hexagonal thread, and M20 flange. The Gas Sampling Unit appears on every HG808 catalogue probe row.
Harsh-environment applications, matched to a model
These are the industrial conditions the HG808 series is specified for. Each card names the recommended model so you can jump to the datasheet or start an inquiry.
Industrial furnaces, kilns and high-temperature ovens
Temperature and humidity monitoring in thermal processing, high-temperature ovens, and coking gas pipelines. Use HG808-T for high-temperature humidity; use HG808-A when the process also needs dew point at elevated temperature.
Continuous high humidity and moisture-intensive processes
Long-term monitoring in high-humidity production areas and other moisture-intensive processes, including humid facilities where condensation is a risk. HG808-H is designed for continuous high-humidity duty (recommended 40–95% RH; maximum recommended 98% RH).
Recommended: HG808-H
Chemical processing and corrosive environments
Processes with acids, alkalis, disinfectants, or selected chemical gases. HG808-F is the corrosion-resistant humidity transmitter (stainless steel housing, IP65). HG808-G measures low dew point in selected chemical gas environments.
Lithium battery manufacturing and dry rooms
Dew-point control on battery drying lines and in dry rooms, including cathode/anode drying. HG808-D is specified for lithium battery manufacturing and dry-gas monitoring. HG808-F is also listed for battery manufacturing where a corrosion-resistant humidity transmitter is required.
Compressed air, glove boxes and industrial dry gas
Inline or process dew-point monitoring in compressed air, dry gas, glove boxes, and semiconductor or controlled-atmosphere lines. HG808-D covers industrial dew point from −60 to +90°C Td; HG808-A is the high-temperature dew-point option for hot drying gas.
Precision manufacturing, laboratories and regulated storage
High-precision temperature and humidity measurement for laboratories, biopharmaceutical production, precision manufacturing, and controlled or food-grade storage. HG808-C is the high-precision model (±0.1°C / ±1.5% RH). HG808-F is listed for pharmaceutical cleanrooms and food-grade environments that also need corrosion resistance.
Outputs and system integration
HG808 series outputs include RS485/Modbus-RTU, 4–20 mA, 0–5 V and 0–10 V, so the transmitter can be wired into a PLC, DCS, or data logger. Confirm the output available on the model you select when you inquire—HG808-D, for example, is listed with 4–20 mA / RS485.
RS485 / Modbus-RTU
Digital bus output for multi-drop industrial networks and remote diagnostics.
4–20 mA
Standard analog current loop for long cable runs into a PLC or panel meter.
0–5 V
Voltage output for controllers and data-acquisition systems that expect a 0–5 V signal.
0–10 V
Voltage output for systems that expect a 0–10 V input.
How to specify an HG808 — and what we can customize
HENGKO is the manufacturer and an OEM factory for this series. Send the process conditions below and we will recommend a model, probe, and fitting. Customization is available where the standard configuration does not fit.
What to include in your inquiry
- Measured variable: temperature and relative humidity, or dew point
- Operating temperature range, and humidity or dew-point range
- Process medium: air, flue or drying gas, compressed air, or a corrosive / chemical gas
- Installation: probe type, inline or duct, thread or flange
- Output required: RS485/Modbus-RTU, 4–20 mA, 0–5 V, or 0–10 V
- Probe style if you already know it (0A#, 3A#, 8A#, and so on)
OEM customization options
- Custom sensor probe lengths, up to 1 meter
- Threaded or flanged mounts to match the process connection
- Custom output signals
- Enhanced IP67 / IP65-rated housings
- Special calibration ranges or field-specific enclosures
All about the HG808 industrial temperature humidity transmitter
Short answers from the live series guide. Open a question for the details, or jump to the compare table for full datasheet figures.
The HG808 series is engineered with robust materials like 316L stainless steel probes and cast aluminum housings, providing high resistance to heat, humidity, and chemical exposure.
Models such as HG808-T and HG808-A are built for extreme temperatures up to 200°C and high-temperature dew point environments, including kilns, ovens, and coking gas pipelines.
Yes. The HG808-T series covers -40°C to +200°C.
The recommended operating range is +85°C to +180°C; below +85°C accuracy is not specified, and +200°C is for short-term use. HG808-A also performs dew point monitoring up to 180°C, for dry high-temperature applications.
These models are widely used in furnace kilns and incinerators, high-temp ovens and drying systems, steel and chemical processing plants, coking or synthesis gas pipelines, and power generation facilities that require dew point control.
Accuracy varies by model. Published figures include HG808-T at ±0.3°C (@85°C) and ±2.5% RH, and HG808-A at ±3°C dew point across -20 to +100°C Td.
See the compare table on this page for the full datasheet values of every model.
Choose the HG808-T series when air temperature exceeds 150°C.
It supports up to 200°C and uses a 316L stainless steel probe that withstands thermal stress and provides stable humidity collection even between 100°C and 200°C. Typical uses include industrial kilns, high-temp drying ovens, and flue gas exhaust pipelines.
Use the HG808-H series in persistently wet or saturated air environments such as greenhouses, swimming pools, fermentation chambers, or cleanrooms.
It is designed with a robust stainless steel sensor housing, an anti-condensation coating, and high humidity tolerance up to 98% RH.
Dew point is the temperature at which air becomes saturated and condensation begins, and it is the more meaningful metric in very dry or pressurized gas systems.
Choose HG808-A for high-temperature and dry applications up to 180°C, or HG808-D / HG808-G for ultra-low dew point detection down to -60°C in glove boxes, lithium battery production, semiconductor packaging, and industrial dry air systems.
The HG808-F series is built for chemical-resistant monitoring in pharmaceutical, chemical processing, and battery manufacturing applications.
It operates at -40 to +120°C and 0–100% RH with a chemical-resistant sensor enclosure, including uses such as cleanrooms (ISO 7–9), battery production, and chemical labs or solvent storage areas.
Choose the HG808-C series for high accuracy and long-term stability.
Published accuracy is ±0.1°C and ±1.5% RH, with a temperature range of -50°C to +150°C. Typical uses include biopharmaceutical manufacturing, calibration labs, food and vaccine storage, and semiconductor packaging rooms.
HG808-D and HG808-G are for inline installation within closed systems such as compressed air lines or glove boxes, and are suited to low dew point (below -20°C) and precise process control.
HG808-A uses an external probe and is suited to open or semi-open high-temp systems, such as heated drying chambers or hot gas ducts, where dew point indicates dryness or condensation risk.
In battery plants, drying rooms require both low humidity and corrosion resistance.
Recommended options on the live series guide are HG808-F for general drying-room humidity monitoring with chemical exposure, HG808-D for inline dew point monitoring in inert gas or vacuum systems, and HG808-G for ultra-dry, low-temp gas streams. Look for a dew point range below -20°C in these scenarios.
Typically no. Sensors that handle extreme temperatures (such as HG808-T, up to 200°C) are not suitable for saturated humidity at those temperatures, while high-humidity sensors such as HG808-H are optimized for moderate temperatures up to 100°C.
Evaluate your application priorities: if temperature is extreme, choose HG808-T; for wet, high-humidity use, choose HG808-H and stay within the specified range.
Choose models with industrial-grade sensors — the HG808 series uses sensors rated for stability and drift resistance — and ensure proper shielding or enclosures if exposed to corrosive vapors or condensation.
Plan for annual recalibration in regulated environments such as pharma or food, and use RS485/Modbus integration for remote diagnostics and maintenance.
Yes. HENGKO supports full OEM customization, including custom sensor probe lengths (up to 1 meter), threaded or flanged mounts, custom output signals, enhanced IP67/IP65-rated housings, and special calibration ranges or field-specific enclosures.
Tell us the condition — we will recommend a configuration
Reach out to the HENGKO team for an HG808 quotation, OEM customization, or application review.