Temperature and Humidity Transmitter
for Humidity Test Chambers

Precision Monitoring Solution for Environmental Test Equipment and Constant temperature and humidity chamber

Why Temperature and Humidity Transmitters Are Essential for Humidity Test Chambers

Ensuring Precision and Stability in Every Climate Simulation

In humidity test chambers, maintaining stable and accurate environmental conditions is critical for reliable testing outcomes. Temperature and humidity transmitters play a central role by providing precise, real-time monitoring and feedback control. Here’s why they are indispensable:

  • Ensure Accurate Environmental Control
    Continuously measure and transmit real-time temperature and humidity data to maintain tight control over test conditions.

  • Improve Test Reliability and Reproducibility
    Help ensure that every test is conducted under consistent conditions, reducing variability and increasing data reliability.

  • Enable Automated Feedback Systems
    Work with the chamber’s control system to automatically adjust heating, cooling, humidification, or dehumidification processes.

  • Support Compliance with Testing Standards
    Provide the accuracy and traceability required to meet ISO, ASTM, or industry-specific testing protocols.

  • Protect Sensitive Products and Materials
    Prevent exposure to unintended environmental deviations, especially important for electronics, pharmaceuticals, and composites.

  • Facilitate Data Logging and Quality Audits
    Allow seamless integration with data acquisition systems for recording, traceability, and documentation.

Why Temperature and Humidity Transmitters Are Essential for Humidity Test Chambers

Technical Requirements for Temperature and Humidity Transmitters in Climate Chambers

✅ 1. Accuracy and Stability (Core Indicators)

Requirement ItemОпис
Точність температуриTypically ±0.1℃ to ±0.2℃; higher precision for pharmaceutical testing
Точність вимірювання вологостіAt least ±1.5%RH; high-end tests require ±1.0%RH or even ±0.8%RH
Long-Term StabilityOne year or longer with minimal drift, reducing recalibration
Response TimeHumidity response time ≤10 seconds for fast system feedback
Drift ControlAnnual drift ≤1.0%RH to ensure test consistency

✅ 2. High-Humidity Operating Capability

Requirement ItemОпис
High-Humidity EnduranceReliable under 90–95%RH or near-saturation for extended periods
Anti-Condensation DesignCoating or heater on sensor surface to prevent condensation
Corrosion ResistanceResistant materials required for pharma, chemical, and defense chambers

✅ 3. Mechanical Design & Installation

Requirement ItemОпис
Compact/Custom DesignSmall form factor or OEM dimension options for tight space
Installation MethodSupports wall-mount, embedded, threaded, flanged, or snap-in installation
Sealing PerformanceHigh-sealing at probe interface to maintain chamber air tightness
Replaceable ProbeQuick-plug for easy maintenance or replacement without full teardown

✅ 4. Output & System Compatibility

Requirement ItemОпис
Output TypeSupports 4–20mA, 0–10V, RS485 Modbus RTU and other industrial standards
Anti-Interference DesignShielded signal cables to ensure stable transmission
Calibration SupportMulti-point or field calibration supported for long-term precision

Why HENGKO's Temperature and Humidity Transmitters are Your Best Choice in Climate Chambers

HG808-H Vs HG808-C Pro Feature Comparison

 What We Can Do for You           HG808-H: Solution       HG808-C Pro: Solution
1. Failure in висока вологість environmentsDesigned for 40–95%RH; supports long-term operation in high humidity. Anti-condensation and anti-mold design with high protection rating to avoid moisture ingress.Also supports stable high humidity operation. Optimized internal structure with strong anti-drift capability.
2. Inadequate humidity точність affects controlProvides ±2%RH accuracy, suitable for general high-humidity control requirements.±0.8%RH ultra-high accuracy, ideal for pharmaceutical stability testing and precise electronics testing.
3. Difficult probe installationSupports various probe forms: direct insertion, extended hose, flange mount. OEM customization for embedded use.Offers compact probe version for tight or sealed chamber installations.
4. Signal compatibility issuesSupports analog (4–20mA / 0–5V / 0–10V) + Modbus RTU / RS485; compatible with PLC, environmental monitoring, and industrial control systems.Same support with dual output, adaptable to different systems.
5. Complex maintenance, long cycleIndustrial-grade housing: dust-proof, corrosion-resistant, long maintenance-free period. Probe can be calibrated or replaced.Minimal accuracy drift, supports multi-point calibration, reduces maintenance cost.
6. Cost control and delivery issues Uses domestic components. 40–60% cost savings compared to Rotronic/Vaisala. Fast OEM delivery.Also cost-effective and suitable as a high-precision domestic alternative.

HG808 Series - Application Matching

Application PositioningProductRecommended Use Scenarios
High-Humidity Specialized Model (Cost-Effective)HG808-HHigh-humidity fermentation chambers, food steam cabinets, constant temperature and humidity chambers, environmental aging chambers
High-Precision Humidity Control (Imported Alternative)HG808-CProPharmaceutical stability test chambers, electronic temperature & humidity reliability test chambers, high-precision inspection chambers

Датчик температури вологості в повітропроводі

HENGKO пропонує широкий асортимент датчиків температури та вологості для будь-яких потреб, від датчиків температури та вологості з нержавіючої сталі до датчиків точки роси. Наші датчики точні, надійні та довговічні, що робить їх ідеальними для широкого спектру застосувань

Піктограма датчика температури та вологості в повітропроводі

4.1 Точка роси RS485 - серія вбудованих датчиків для повітропроводів

HENGKO пропонує широкий асортимент датчиків температури та вологості для будь-яких потреб, від датчиків температури та вологості з нержавіючої сталі до датчиків точки роси. Наші датчики точні, надійні та довговічні, що робить їх ідеальними для широкого спектру застосувань

HG808-H

  • Висока вологість / Висока вологість в умовах підвищеної вологості 98% Датчик вологості RH
    Розроблено для постійної експлуатації в умовах підвищеної вологості, чистих приміщеннях і басейнах.
  • Постійне середовище з високою вологістю >85%RH, точна та довговічна робота

What Process of Constant temperature and humidity chamber need to Monitor Temperature and Humidity ?

Monitoring temperature and humidity is essential at multiple stages of the operation of a constant temperature and humidity chamber (climate chamber) to ensure accurate simulation of environmental conditions and compliance with testing standards. The key processes that require real-time temperature and humidity monitoring include:


1. Environmental Conditioning / Pre-Stabilization

  • Purpose: To bring the chamber environment to the target temperature and humidity setpoint before introducing test samples.

  • Monitoring Role: Sensors verify that the chamber has reached the desired stable condition (e.g., 25°C ±0.2°C / 60%RH ±2%RH) before testing begins.


2. Sample Testing / Soak Period

  • Purpose: To expose materials, products, or components to precise and stable environmental conditions over a defined duration.

  • Monitoring Role: Continuous feedback from temperature and humidity transmitters allows the control system to make fine adjustments. This ensures uniformity and prevents deviations that could invalidate test results.


3. Data Logging and Validation

  • Purpose: To record environmental data for quality assurance, regulatory compliance (e.g., FDA, ICH, ISO), and traceability.

  • Monitoring Role: Transmitters provide high-resolution, time-stamped data to the chamber’s data logger or external system to verify environmental conditions throughout the test duration.


4. Closed-Loop Control Operation

  • Purpose: To automatically regulate heating, cooling, humidification, and dehumidification systems.

  • Monitoring Role: Real-time data from the sensors is used by the PID control algorithm to maintain tight environmental tolerances, responding to internal or external fluctuations.


5. Alarm & Fault Detection

  • Purpose: To detect deviations or failures (e.g., heater/humidifier malfunctions or door leaks).

  • Monitoring Role: The transmitter triggers alarms when temperature or humidity values fall outside of acceptable limits, helping prevent damage to test samples and ensuring system reliability.


6. Calibration and Maintenance Feedback

  • Purpose: To maintain sensor performance over time and ensure test validity.

  • Monitoring Role: Monitoring trends in sensor drift or inconsistency helps schedule timely recalibration and reduce unplanned downtime.

5-Factors You Should Care When Choose Humidity Transmitter for Your Constant temperature and humidity chamber ?

Here are 5 factors you should consider when buy a humidity transmitter for your Climate Chambers:

1. High Accuracy & Stability

Look for ±1.0%RH or better and ≤1%RH/year drift to ensure reliable test data.

2. High-Humidity Resistance

Must operate long-term in 90–95%RH. Anti-condensation coating and corrosion-resistant housing are essential.

3. Fast Response Time

Response ≤10s helps maintain tight control via closed-loop feedback systems.

4. Signal Compatibility

Supports 4–20mA, 0–10V, or RS485 Modbus to fit your control and monitoring systems.

5. Easy Installation & Maintenance

Compact probes, replaceable elements, and field calibration save time and reduce downtime.

ПОШИРЕНІ ЗАПИТАННЯ

A temperature and humidity transmitter is a critical component in humidity test chambers, responsible for accurately monitoring and transmitting real-time environmental data. It helps maintain the desired climate conditions by feeding precise temperature and humidity readings to the chamber’s control system. This ensures consistency, repeatability, and compliance with testing standards, especially in industries like pharmaceuticals, electronics, and materials testing.

For high-reliability applications such as pharmaceutical stability testing or electronic component reliability, humidity transmitters should offer an accuracy of ±1.0%RH or better, with premium models achieving ±0.8%RH. Temperature accuracy should typically be within ±0.1°C to ±0.2°C. The sensor must also demonstrate low drift over time (≤1.0%RH/year) and fast response times (≤10 seconds) to meet strict control requirements.

Common failure risks include:

  • Condensation buildup on the sensor element, causing reading errors or corrosion.

  • Microbial growth due to prolonged exposure to high moisture.

  • Signal drift or loss of calibration over time.

  • Ingress of water vapor damaging internal electronics.
    To mitigate these risks, industrial-grade transmitters are designed with anti-condensation coatings, sealed housings, sensor heatersі corrosion-resistant materials (e.g., 316L stainless steel or PBT enclosures).

No, standard HVAC humidity transmitters are typically not suitable for the rigorous and high-humidity operating conditions of climate or test chambers. They often lack the necessary:

  • Measurement accuracy

  • Environmental sealing

  • Condensation protection

  • Довгострокова стабільність
    Industrial or laboratory-grade transmitters are specifically designed to operate in 90–95%RH, with strong resistance to drift, corrosion, and electrical interference, making them essential for reliable test chamber operation.

The most commonly used output signals include:

  • Analog outputs: 4–20mA or 0–10V, suitable for direct connection with PLCs or analog controllers.

  • Digital outputs: RS485 with Modbus RTU protocol, allowing for long-distance, multi-point data collection and integration with modern data logging systems.
    A dual-output model (e.g., analog + Modbus) is often preferred for flexible integration and redundancy.

Calibration frequency depends on the application, sensor stability, and regulatory requirements. In general:

  • High-precision applications (e.g., pharmaceutical stability chambers): calibrate every 6–12 months.

  • General industrial use: annual calibration may suffice if the sensor is stable.
    Choose transmitters with low drift specifications, multi-point calibration supportі field calibration options to minimize downtime and ensure traceability.

FIND RIGHT TEMPERATURE & HUMIDITY TRANSMITTER

Розкажіть нам про свій проект сьогодні

Розкажіть нам про свій моніторинговий проект,
Ми надамо вам найкраще рішення за конкурентними цінами протягом 3 днів.

Поширюй світ

HENGKO є світовим лідером у галузі промислових сенсорних рішень, з репутацією унікального дизайну та відмінними характеристиками. Наші датчики температури та вологості використовуються в широкому спектрі галузей промисловості, включаючи харчову, фармацевтичну, виробничу та екологічний моніторинг.

0 +

Багаторічний досвід

0

Продажі по всьому світу

0 K

Промислові проекти

Інші популярні проекти

Винні погреби

Удосконалення консервації: Управління температурою та вологістю для витримки вина

Лікарні та лабораторії

Точність в охороні здоров'я: Забезпечення стерильності та стабільності середовища

Сільськогосподарські склади

Оптимізація зберігання врожаю: Стабілізація умов після збору врожаю
ukUkrainian

ЗВ'ЯЗАТИСЯ З НАМИ

З усіх питань, будь ласка, звертайтеся за адресою: