High temperature and humidity Split Probe portable dew point temperature meter

The HENGKO HG-982 Handheld Dewpoint Meter is a versatile tool designed for spot-checking applications and field calibration in various industrial settings. It provides accurate and fast measurements of dew point, temperature, relative humidity, and wet bulb temperature.

Artikel: HG982

Produktparameter

  • Temperaturbereich: -30℃~+120℃ max, for the probe
  • Luftfeuchtigkeitsbereich: 0%RH-99.9%RH
  • Dew Point range: -50 ~ 80 °C (-58 ~ 176 °F)
  • Genauigkeit der externen Sonde: ±1.5%RH, ±0.4℃(25℃)
  • Web range: -20~60℃, ±0.5℃(25℃)
  • Multiple units of measure: °C, °F, ppm, g/m³, g/kg
  • Large backlit LCD display: Bei allen Lichtverhältnissen leicht zu lesen
  • Data logging and export: Ermöglicht das Speichern und Analysieren Ihrer Daten
  • Datenspeicherung: 32000-64000
  • Data Output: USB-Anschluss, 99-Data kann direkt verwendet werden 
  • Compact and portable design: Einfacher Einsatz vor Ort und im Feld
  • Rugged and durable construction: Gebaut, um rauen industriellen Umgebungen zu widerstehen

SPEZIFIKATION

Produkt-Highlights:

Schnelle Reaktion, das Produkt verwendet 316L-Edelstahl-Sonde
Schale, widerstandsfähiger;
Wasser- und staubdicht nach IP66, für den Einsatz unter rauen Bedingungen geeignet
Bietet langfristige Genauigkeit unter Umweltbedingungen;
Einfache Schnittstelle, einfach zu verwenden, einfach zu bedienen, keine Notwendigkeit für professionelle
Ausbildung des Fachpersonals;
Außerdem verfügt es über einen hochauflösenden Großbildschirm mit Hintergrundbeleuchtung, so dass das Produkt auch in der prallen Sonne gut zur Geltung kommt.
Die Daten können auch in dunklen Umgebungen bei Nacht normal angezeigt werden;
Verbinden Sie sich mit Bluetooth, überwachen Sie Daten in Echtzeit, und erstellen Sie automatisch Daten
Die Datentabelle kann 99 Datensätze speichern.

handheld temperature and humidity meter instruction
Tragbares Temperatur-Feuchtigkeitsmessgerät Artikel Option von HENGKO

FAQ

A split probe portable dew point temperature meter is a precision instrument designed to measure dew point, temperature, and humidity in environments characterized by high temperature and humidity levels. The device consists of two main components: a sensor probe and a display unit. The sensor probe, equipped with specialized sensors, is placed in the measurement environment while the display unit provides readings and controls.

The dew point is determined by cooling a mirror surface until condensation forms, at which point the temperature of the mirror is recorded as the dew point. The meter calculates relative humidity, absolute humidity, and other parameters based on the dew point and temperature measurements. These instruments often employ advanced algorithms and compensation techniques to ensure accurate readings in challenging conditions.

High temperature and humidity split probe dew point meters find applications in various industries where precise moisture control is critical. Some common applications include:

  • Industrielle Prozesse: Monitoring and controlling humidity in manufacturing processes, drying, and curing operations.
  • HLK-Systeme: Optimizing system performance, preventing condensation, and ensuring indoor air quality.
  • Pharmaceutical and biotechnology: Maintaining controlled environments for product stability and safety.
  • Food processing: Monitoring moisture content in products and preventing spoilage.
  • Meteorology and environmental monitoring: Measuring atmospheric humidity for weather forecasting and climate studies.

Choosing the right dew point meter depends on specific application requirements. Key factors to consider include:

  • Temperature and humidity range: Ensure the meter’s specifications match the environmental conditions.
  • Genauigkeit: Select a meter with the required precision for your application.
  • Probe length and material: Consider the distance between the sensor and display unit, as well as the probe’s compatibility with the environment.
  • Data logging capabilities: Determine if data recording and storage are necessary.
  • Display features: Evaluate the clarity and functionality of the display.
  • Calibration and maintenance requirements: Assess the ease of calibration and ongoing maintenance.

Calibration is essential for maintaining the accuracy of a dew point meter. The calibration process typically involves using a traceable humidity standard to adjust the meter’s readings. It’s recommended to follow the manufacturer’s calibration procedures and use certified calibration equipment. Regular calibration intervals should be established based on the meter’s usage and the criticality of the measurements.

Proper care and maintenance prolong the life and accuracy of the meter. Key maintenance practices include:

  • Regular cleaning of the sensor probe to prevent contaminants from affecting measurements.
  • Protecting the meter from physical damage and extreme environmental conditions.
  • Storing the meter in a controlled environment when not in use.
  • Following the manufacturer’s recommended maintenance schedule.