Industrial Temperature & Humidity Transmitter

Spec the right HG803 — mount, probe, and output in three steps.

Field measurement challenges

Industrial temperature & humidity problems HG803 is built to handle

Six field pains — dust, duct air, PLC signals, harsh installs, service downtime, and dew-point blind spots — and how HG803 probe design and outputs address them.

HENGKO HG803 stainless steel porous metal probe temperature humidity transmitter IP66

Dust, moisture & condensation attack open sensors

Unprotected humidity elements foul or drift when dust and condensate reach the sensing film.

  • Porous stainless / plastic caps
  • IP66 enclosure options
  • Shielded ambient & process RH
See probe series
HENGKO HG803 duct flange humidity temperature sensor for HVAC air streams

Wall sensors miss HVAC duct air

Room transmitters miss stratified supply/return air — lag, condensation risk, wasted energy.

  • Plastic or SS flange / screw duct probes
  • 15 cm & 20 cm insertion lengths
  • Split / integrated for true room duty
Choose duct vs wall
HENGKO HG803 temperature humidity transmitter with LCD display and RS485 4-20mA outputs

PLC / BMS need the right signal

Projects stall when you have RS485 but need 4-20mA — or operators need a local readout.

  • RS485 Modbus dew-point / T&H
  • Dual 4-20mA + RS485; voltage + RS485
  • Optional LCD for commissioning
Match output & display
HENGKO HG803 split remote probe temperature humidity transmitter for process mounting

Harsh temperature & awkward mounts

Electronics cannot sit in the hot or hard-to-reach point; threaded or flanged stems are required.

  • SS remote probes typically −40~120°C
  • Plastic probes for milder ambient
  • Threaded, short/long flange + cable
Ask about your environment
HENGKO HG803 replaceable plastic remote probe for field maintenance

Drift & downtime without serviceable probes

In dirty or high-RH service, replacing the whole head is costly when only the probe aged out.

  • Split replacement probe series
  • Keep wiring; swap the sensing probe
  • Auto-cal notes — confirm per manual
View replaceable models
HENGKO HG803 dew point temperature humidity transmitter with display for condensation control

RH-only blind spot for condensation & dew point

Tracking %RH alone misses when surfaces will wet — cold rooms, ducts, and dryers need dew point.

  • Dew point on digital RS485 models
  • Display SKUs for local Td checks
  • Pair with duct / process probe choice
Filter dew-point models
Interactive selector

Choose the right HG803 in three steps

Mount type → probe style → output & display. We recommend 1–3 model codes you can quote or open in the compare table.

Output

Display

HG803 series

Four series — not dozens of duplicate cards

Browse by installation family, then open the filtered compare table for every SKU and output option.

HENGKO HG803 split probe temperature humidity transmitter with remote sensor

Split Probe Series

Remote probe + wall-mounted transmitter for industrial ambient and process points. Plastic or stainless probes (standard, threaded, short/long flange).

  • Outputs: RS485 dew point, 4-20mA+RS485, 0-5V / 0-10V + RS485
  • Metal: -40~120°C (work <110°C) · Plastic: -40~100°C (work <80°C)
  • IP66 · optional display · wall mounted
View in compare table
HENGKO HG803 temperature humidity transmitter with replaceable remote sensor probe

Split Replacement Probe Series

Field-replaceable plastic probe — swap sensors without rewiring the transmitter head in high-humidity service.

  • Replaceable plastic remote probe
  • RS485 dew point or 4-20mA + RS485 (also 0-5V / 0-10V)
  • -40~100°C · work <80°C · IP66 · display optional
View in compare table
HENGKO HG803 integrated temperature humidity transmitter with digital display

Integrated Probe Series

Compact all-in-one plastic body for rooms, cabinets, and general ambient monitoring.

  • Plastic integrated probe
  • Same digital / analog output matrix as split family
  • Typical listed range -20~60°C · IP66 · display optional
View in compare table
HENGKO HG803 duct mounted temperature humidity sensor with flange probe

Duct Humidity Temperature Sensor Series

Flange and screw duct probes (15 cm / 20 cm SS or plastic flange) for AHUs and HVAC air streams.

  • RS485 dew point or 4-20mA + RS485
  • -40~80°C measurement · duct / pipeline / HVAC
  • IP66 · with / without display
View in compare table

Not sure which of 76 models? Tell us your mount and PLC input — we will reply with a 3-model shortlist, typically within 24 hours.

Get a shortlist
Applications

Where industrial temperature humidity transmitters earn their keep

Tap an application to prefill your inquiry — we will recommend probe and output for that environment.

HVAC ducts & AHUs

Supply/return duct T&H for comfort control, dehumidification, and condensation prevention. Prefer duct flange or screw probes.

Request quote

Warehouses & cold chain

Ambient monitoring with wall-mounted split or integrated units; RS485 networks for multi-zone logging.

Request quote

Greenhouses & agriculture

Stable humidity and dew-point awareness for crop climate control; plastic probes for milder chemical exposure.

Request quote

Pharma & cleanrooms

Controlled environments needing reliable T/RH transmission to BMS — discuss calibration and display needs with sales.

Request quote

Food processing

Process areas where dust, wash-down adjacency, and stainless probes matter; dual 4-20mA+RS485 for plant PLCs.

Request quote

Data centers & telecom rooms

Room and rack-adjacent humidity control to protect equipment; integrated or split plastic probes with Modbus RS485.

Request quote
Model matrix

Filterable HG803 compare table

Hover Model, Display, or Probe for a thumbnail; click to open a large image. Filter by series, output, and display. On a phone, tap a selector option to preview its photo, and tap a model or probe name in the table to enlarge.

HG803 temperature humidity transmitter compare matrix — series, output, display, probe, and dew point notes
ModelProbe TypeOutputDisplayMeasurementTemp RangeProbe / ApplicationCTA
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~100°C
Plastic protective cap; water- and dust-resistant; IP66; work <80°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Stainless steel protective cap; IP66; work <110°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Threaded SS porous metal probe; IP66; work <110°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Short flange SS probe; wall/pipe mount; IP66; work <110°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Remote Probe RS485 Dew Point Dew Point / Temp & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Remote Probe 4-20mA + RS485 Temperature & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Remote Probe 0-5V + RS485 Temperature & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Remote Probe 0-10V + RS485 Temperature & Humidity -40~120°C
Long flange SS probe; deeper insertion; IP66; work <110°C
Contact
Integrated Probe RS485 Dew Point Dew Point / Temp & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Integrated Probe RS485 Dew Point Dew Point / Temp & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Integrated Probe 4-20mA + RS485 Temperature & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Integrated Probe 4-20mA + RS485 Temperature & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Integrated Probe 0-5V + RS485 Temperature & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Integrated Probe 0-5V + RS485 Temperature & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Integrated Probe 0-10V + RS485 Temperature & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Integrated Probe 0-10V + RS485 Temperature & Humidity -20~60°C
Compact plastic integrated body; ambient monitoring
Contact
Remote Probe (Replaceable) RS485 Dew Point Dew Point / Temp & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Remote Probe (Replaceable) RS485 Dew Point Dew Point / Temp & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Remote Probe (Replaceable) 4-20mA + RS485 Temperature & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Remote Probe (Replaceable) 4-20mA + RS485 Temperature & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Remote Probe (Replaceable) 0-5V + RS485 Temperature & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Remote Probe (Replaceable) 0-5V + RS485 Temperature & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Remote Probe (Replaceable) 0-10V + RS485 Temperature & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Remote Probe (Replaceable) 0-10V + RS485 Temperature & Humidity -40~100°C
Replaceable plastic probe; high-humidity friendly; work <80°C
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Air ducts / HVAC; plastic flange
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Air ducts / HVAC; plastic flange
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Air ducts / HVAC; plastic flange
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Air ducts / HVAC; plastic flange
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct flange mount; 15 cm SS probe
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct flange mount; 15 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct flange mount; 15 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct flange mount; 15 cm SS probe
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct flange mount; 20 cm SS probe
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct flange mount; 20 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct flange mount; 20 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct flange mount; 20 cm SS probe
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct screw/thread mount; 15 cm SS probe
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct screw/thread mount; 15 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct screw/thread mount; 15 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct screw/thread mount; 15 cm SS probe
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct screw/thread mount; 20 cm SS probe
Contact
Duct-Mounted Probe RS485 Dew Point Dew Point / Temp & Humidity -40~80°C
Duct screw/thread mount; 20 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct screw/thread mount; 20 cm SS probe
Contact
Duct-Mounted Probe 4-20mA + RS485 Temperature & Humidity -40~80°C
Duct screw/thread mount; 20 cm SS probe
Contact

Showing 76 of 76 models

Encoding: 1/3/5/7 = no display · 2/4/6/8 = with display · 8P ≈ RS485 dew point · 4P ≈ 4-20mA+RS485 · 5P ≈ 0-5V+RS485 · 1P ≈ 0-10V+RS485. Photos: exact model when available, else closest probe-family image from hengkometer.com.

Seen the matrix? Send 1–3 candidate codes — we confirm probe, output, and cable length before you purchase.

Confirm my shortlist
Selection guide

How to choose an industrial temperature humidity transmitter

Three decisions cover most HG803 projects — then confirm output with your PLC or BMS.

1

Install location

Wall / remote process → Split. Compact room → Integrated. Air duct → Duct flange or screw. Need probe swaps → Replaceable.

2

Probe material & shape

Plastic for milder ambient; stainless for dust and higher temperature. Threaded or flanged stems for insertion depth.

3

Output & display

Modbus RS485 with dew point, dual 4-20mA + RS485, or 0-5V / 0-10V + RS485. Add LCD when operators need a local readout.

Product demo

See the HG803 temperature humidity transmitter in action

Short walkthrough of the industrial HG803 platform — probe styles, display, and how teams specify RS485 / 4-20mA transmitters for real installs.

Watch on YouTube, then shortlist models with the selector or send your mount and PLC input for a quote.

Proof & capability

Published HG803 specs you can verify

Facts below come from HENGKO’s HG803 manuals and catalogue. Review the documents, then talk to engineering about your SKU mix.

  • IP66 enclosure options for dusty and wet industrial installs across the HG803 family.
  • Modbus RS485 dew-point digital output, plus dual 4-20mA + RS485 and voltage + RS485 variants for PLC / BMS.
  • Platform notes cover automatic calibration and wide-voltage overcurrent protection.
  • Digital dew-point / T&H path listed at 0.01 resolution; analog dual 4-20mA uses high-resolution conversion.
  • Typical listing: 1.5 m head cable; probe extensions up to 20 m — confirm length per datasheet.
  • Probe windows published by series (metal work <110°C, plastic <80°C, duct −40~80°C).

sales@hengkometer.com · +86-755-88823250 · OEM / ODM project support

HENGKO HG803 Series industrial temperature humidity transmitter specs — IP66, Modbus RS485, 4-20mA, probe options
Honeywell — brand referenced on HENGKO site
Emerson — brand referenced on HENGKO site
FOXCONN — brand referenced on HENGKO site
P&G — brand referenced on HENGKO site
CRRC — brand referenced on HENGKO site
CASC — brand referenced on HENGKO site
CETC — brand referenced on HENGKO site
Great Wall — brand referenced on HENGKO site
Solvay — brand referenced on HENGKO site
SGS — brand referenced on HENGKO site

Brand marks shown on hengkometer.com under “Trusted by 100 world-class brands and organizations.” Logos are site assets for social proof — not a claim of exclusive partnership.

OEM & customization

Build your HG803 around the install — not the other way around

HENGKO manufactures the HG803 platform for project OEMs, HVAC wholesalers, and integrators who need probe, cable, output, and branding options without starting a new transmitter family.

HENGKO HG803 OEM and customization — probe geometry, output, cable, display, replaceable probe
  • Probe geometry & filterSplit, integrated, or duct mounts; sintered metal filters for dusty HVAC and process air.
  • Output & protocolRS485 Modbus dew point, dual 4-20mA + RS485, or voltage + RS485 matched to your PLC / BMS I/O.
  • Cable length & connectorsFactory cable length and connector choices for panels, ducts, and remote sensors.
  • Display & private labelLCD or blind head; discuss branding and packaging for qualified wholesale volumes.
  • Replaceable probe pathServiceable probe SKUs so field teams swap sensors without rewiring the transmitter body.

Share environment, preferred output, and volume band — engineering returns an HG803 shortlist from the manufacturer catalogue (no invented prices on this page).

Next step

Get probe advice before you lock the P.O.

No fake countdown timers — just a fast engineering reply grounded in how HENGKO already supports customize, OEM, and partner marketing.

  • Free probe / output advice — typically within 24 hours
  • Custom probe geometry & cable length on the HG803 platform
  • Sample & OEM discussion for qualified projects
  • Marketing assets for distributors (images, videos)
Why HENGKO

Manufacturer strengths for partners & OEMs

Commercial strengths for distributors, HVAC wholesalers, and OEM buyers specifying HENGKO temperature humidity transmitters.

Customize

Customize dew point transmitter and probe configurations based on HENGKO’s self-designed HG803 platform.

Competitive price

Cost-effective manufacturing for project volumes and distributor programs — request a quote for your SKU mix.

Upgrading products

Ongoing upgrades so your catalogue keeps pace with industrial and HVAC market needs.

Marketing support

High-resolution images, 3D-effect videos, and sales materials to help partners sell successfully.

FAQ

Industrial temperature humidity transmitter FAQ

Concise answers for engineers specifying industrial dew point, RS485, and 4-20mA humidity transmitters.

The HENGKO HG803 is an industrial temperature humidity transmitter family for HVAC ducts, warehouses, greenhouses, and process rooms. It measures temperature and relative humidity, calculates dew point on digital models, and outputs RS485 Modbus and/or 4-20mA (IP66 enclosure options) to a PLC, BMS, or recorder. Manufacturer site: hengkometer.com.

Most industrial transmitters use capacitive polymer elements: moisture changes the dielectric of a sensing film, converted to %RH. Temperature is measured separately; dew point can be calculated on digital RS485 models.

4-20mA is a noise-resistant industrial current loop for long cable runs and wide PLC compatibility. HG803 dual-output models combine 4-20mA with RS485 for analog points plus a digital bus.

HVAC ducts and AHUs, warehouses and cold chain, greenhouses, pharma/cleanroom monitoring, food processing, and data centers / telecom rooms. Use the Applications tiles to prefill your inquiry for that use case.

Use the on-page selector: mount first, then probe material/length, then output and display. Match temperature range and IP66 environment to your process.

Example HG803-2W8P-04: display digit (1/3/5/7 = no display, 2/4/6/8 = with display), output (8P dew-point RS485, 4P 4-20mA+RS485, 5P 0-5V+RS485, 1P 0-10V+RS485), suffix for probe style.

Yes. OEM/ODM customization on the HG803 platform (probe geometry, cable length, output mix). Contact sales@hengkometer.com or +86-755-88823250.

HG803 Temperature and Humidity Transmitter Manual (PDF) and the 2024 Temperature Humidity Sensor Catalogue are linked in the Proof section above on hengkometer.com.

Request a quote

Talk to HENGKO about your HG803 project

Model and application fields auto-fill from selector, table, and application CTAs. We confirm probe, output, cable length, and lead time.

Front-end form opens mailto:sales@hengkometer.com. No prices listed — quotes on request.

CONTACT US

For all inquiries, please feel free to reach out at: