Industrial dew point measurement

Industrial Dew Point Transmitters for Dry Gas, Corrosive and High-Temperature Processes

Select a compact inline HG602, an industrial box-type HG808 with a split probe, or a handheld meter — then inquire with your process conditions.

−60°C Td low-range models to −60°C

16 bar pressure resistance

RS485 + analog Modbus-RTU, 4–20 mA / 0–5 V / 0–10 V

Video poster: How Dew Point Sensors Make Factories Safer!

A YouTube video, “How Dew Point Sensors Make Factories Safer!”, can be played in this section. If the player does not load, open https://www.youtube.com/watch?v=PQUK1QSwNd0

Manufacturer

OEM / ODM

Industrial dew point

sales@hengkometer.com

+86-755-88823250

An industrial dew point transmitter measures the dew-point temperature of a process gas — the temperature at which moisture would condense — and outputs that value, often together with temperature and humidity, as an analog and/or RS485 Modbus-RTU signal for PLC or DCS monitoring. HENGKO HG602 compact inline transmitters and HG808 box-type transmitters are specified for industrial gases, compressed air and demanding process conditions.

Why this range

Match the transmitter to the condition — not the other way around

Dry gas, corrosive chemistry and high-temperature processes fail ordinary humidity transmitters in different ways. This range is organised by those conditions, and by whether you need a compact inline body or an industrial box with a split probe.

HG808 + HG602

Compact inline, limited space

HG602 is a highly integrated pipeline transmitter with a G1/2" process connection, built for confined industrial installations and OEM equipment.

Recommended: HG602-D · HG602-G · HG602-C

Industrial box, split probe, display

HG808 uses an aluminium-alloy housing, a split or duct-type probe, a local display and keypad, and on-board recording — suited to cabinets, lines and systems that need a serviceable remote probe.

Recommended: HG808-D · HG808-G · HG808-A

Corrosive, chemical or battery dry rooms

G models use a corrosion-resistant construction (316L with a protective coating on HG808-G and HG602-G) for acids, alkalis, solvents, salt spray and process gases such as HF or ammonia.

Recommended: HG602-G · HG808-G

Ultra-high temperature processes

HG808-A is specified for a temperature range of 0…+180°C and a dew-point range of −20…+100°C, for drying rooms, flue-gas related service and high-temperature vacuum work.

Recommended: HG808-A

Refrigerated dryers and compact OEM

HG602-C is the minimal-type compact transmitter designed for refrigerated air dryers, with the tightest catalogue Td accuracy in this lineup (±1°C) and a −30…+50°C dew-point range.

Recommended: HG602-C

Portable inspection and verification

When you need a meter in the hand rather than a fixed 4–20 mA / RS485 loop, the catalogue lists three dew-point handhelds: replaceable-probe HG970, high-temperature HG981, and split-type HG982.

Recommended: HG970 · HG981 · HG982

Select a model by condition

Model selector

Choose the right dew point instrument in three steps

Start with how you will use it, then the operating condition and installation style. Step 3 only configures probes, fittings or outputs — it does not change the recommended model.

What do you need?

Operating condition and installation style

Recommended model

HG602-D · Precision & Stable Type

Compact inline transmitter for dry industrial gases, compressed-air dryers, glove boxes and OEM pipelines.

  • Dew point −60 … +60°C, accuracy ±2°C Td
  • Operating temperature −40 … +60°C; pressure resistance 16 bar; IP65
  • Outputs 4–20 mA / 0–5 V / 0–10 V + RS485; G1/2" thread

Recommended model

HG602-G · Corrosion-Resistant

Compact inline transmitter for HF, chlorine, ammonia, oil mist, salt spray and organic solvents — including lithium-battery and chemical lines.

  • Dew point −60 … +20°C, accuracy ±3°C Td
  • Operating temperature −40 … +60°C; 16 bar; IP65; coated stainless housing
  • Outputs 4–20 mA / 0–5 V / 0–10 V + RS485

Recommended model

HG602-C · Minimal Type

Compact transmitter designed for refrigerated air dryers, with the tightest Td accuracy in this catalogue lineup.

  • Dew point −30 … +50°C, accuracy ±1°C Td
  • Operating temperature −20 … +50°C; 16 bar; IP65
  • Outputs 4–20 mA / 0–5 V / 0–10 V + RS485; G1/2"

Recommended model

HG808-D · Precision & Stability

Box-type online transmitter for low-humidity and dry or inert gases — compressed air, semiconductor protective gas and similar service. Use away from corrosive media, oil or chemical vapours.

  • Dew point −60 … +90°C, accuracy ±2°C Td
  • Temperature range −40 … +90°C; transmitter operating range −20 … +60°C
  • Probes 0A#, 0B#, 8A#, 8B#; pressure resistance 16 bar

Recommended model

HG808-G · Corrosion-Resistant

Box-type transmitter with 316L probe, protective coating and IP65 cast-aluminum housing for chemical, pharmaceutical and new-energy dry processes.

  • Dew point −60 … +20°C, accuracy ±3°C Td
  • Probes 0A# and 8A# only; 16 bar; IP65
  • RS485 / Modbus-RTU plus 4–20 mA / 0–5 V / 0–10 V (choose one analog)

Recommended model

HG808-A · Ultra-High Temperature

Box-type transmitter for high-temperature drying, petrochemical and vacuum processes. Temperature range 0…+180°C.

  • Dew point −20 … +100°C, accuracy ±3°C Td
  • Temperature range 0 … +180°C (catalogue does not state +200°C)
  • Probes 0A#, 0B#, 8A#, 8B#; 16 bar

Recommended model

HG970 · Replaceable Probe Handheld

Portable dew-point meter with a replaceable probe, USB data recording, and a probe temperature range of −30…+80°C. Listed in the catalogue as a handheld temperature and humidity dew point meter (TOC: calibrator).

  • Dew point −30 … +80°C (Td accuracy not stated in the catalogue)
  • Temperature accuracy ±0.1°C (@20°C); humidity ±1.5% RH
  • Replaceable probe; USB recording; 316L / IP66 family probe housing

Recommended model

HG981 · High-Temperature Handheld

Compact handheld for on-site inspection at elevated temperature. Probe temperature range −30…+120°C; the catalogue highlights +80…+120°C as the highly recommended use band.

  • Dew point −30 … +80°C; temperature −30 … +120°C
  • 316L probe housing, IP66; Bluetooth (customisable); 99 data sets
  • Td accuracy is not stated in the catalogue

Recommended model

HG982 · Split Type Handheld

Split-type handheld with a coiled cable and a long external probe for ovens, dryers, narrow spaces and equipment cavities.

  • Dew point −30 … +80°C; probe temperature −30 … +120°C
  • USB recording; 316L / IP66; optional Bluetooth
  • Td accuracy is not stated in the catalogue

Optional configuration — does not change the recommended model

Product preview

Recommended model

HG602-D · Precision & Stable Type

Compact inline transmitter for dry industrial gases, compressed-air dryers, glove boxes and OEM pipelines.

  • Dew point −60 … +60°C, accuracy ±2°C Td
  • Operating temperature −40 … +60°C; pressure resistance 16 bar; IP65
  • Outputs 4–20 mA / 0–5 V / 0–10 V + RS485; G1/2" thread

Recommended model

HG602-G · Corrosion-Resistant

Compact inline transmitter for HF, chlorine, ammonia, oil mist, salt spray and organic solvents — including lithium-battery and chemical lines.

  • Dew point −60 … +20°C, accuracy ±3°C Td
  • Operating temperature −40 … +60°C; 16 bar; IP65; coated stainless housing
  • Outputs 4–20 mA / 0–5 V / 0–10 V + RS485

Recommended model

HG602-C · Minimal Type

Compact transmitter designed for refrigerated air dryers, with the tightest Td accuracy in this catalogue lineup.

  • Dew point −30 … +50°C, accuracy ±1°C Td
  • Operating temperature −20 … +50°C; 16 bar; IP65
  • Outputs 4–20 mA / 0–5 V / 0–10 V + RS485; G1/2"

Recommended model

HG808-D · Precision & Stability

Box-type online transmitter for low-humidity and dry or inert gases — compressed air, semiconductor protective gas and similar service. Use away from corrosive media, oil or chemical vapours.

  • Dew point −60 … +90°C, accuracy ±2°C Td
  • Temperature range −40 … +90°C; transmitter operating range −20 … +60°C
  • Probes 0A#, 0B#, 8A#, 8B#; pressure resistance 16 bar

Recommended model

HG808-G · Corrosion-Resistant

Box-type transmitter with 316L probe, protective coating and IP65 cast-aluminum housing for chemical, pharmaceutical and new-energy dry processes.

  • Dew point −60 … +20°C, accuracy ±3°C Td
  • Probes 0A# and 8A# only; 16 bar; IP65
  • RS485 / Modbus-RTU plus 4–20 mA / 0–5 V / 0–10 V (choose one analog)

Recommended model

HG808-A · Ultra-High Temperature

Box-type transmitter for high-temperature drying, petrochemical and vacuum processes. Temperature range 0…+180°C.

  • Dew point −20 … +100°C, accuracy ±3°C Td
  • Temperature range 0 … +180°C (catalogue does not state +200°C)
  • Probes 0A#, 0B#, 8A#, 8B#; 16 bar

Recommended model

HG970 · Replaceable Probe Handheld

Portable dew-point meter with a replaceable probe, USB data recording, and a probe temperature range of −30…+80°C. Listed in the catalogue as a handheld temperature and humidity dew point meter (TOC: calibrator).

  • Dew point −30 … +80°C (Td accuracy not stated in the catalogue)
  • Temperature accuracy ±0.1°C (@20°C); humidity ±1.5% RH
  • Replaceable probe; USB recording; 316L / IP66 family probe housing

Recommended model

HG981 · High-Temperature Handheld

Compact handheld for on-site inspection at elevated temperature. Probe temperature range −30…+120°C; the catalogue highlights +80…+120°C as the highly recommended use band.

  • Dew point −30 … +80°C; temperature −30 … +120°C
  • 316L probe housing, IP66; Bluetooth (customisable); 99 data sets
  • Td accuracy is not stated in the catalogue

Recommended model

HG982 · Split Type Handheld

Split-type handheld with a coiled cable and a long external probe for ovens, dryers, narrow spaces and equipment cavities.

  • Dew point −30 … +80°C; probe temperature −30 … +120°C
  • USB recording; 316L / IP66; optional Bluetooth
  • Td accuracy is not stated in the catalogue
Product range

Three families, organised the way you specify

The 2026 catalogue groups dew-point instruments as compact inline HG602 transmitters, box-type HG808 online transmitters, and handheld dew-point meters. Figures below are taken from that catalogue.

HG602 Series — compact inline dew point transmitters

A highly integrated G1/2" pipeline body for confined industrial installations. Type A is the compact single-cable body; Type B adds dual aviation connectors and an LED alarm. All three models list 4–20 mA / 0–5 V / 0–10 V + RS485, IP65 and 16 bar pressure resistance.

HENGKO HG602-D compact dew point transmitter, Type A upright body and Type B angled body with LED

HG602-D

Precision & Stable Type

  • Compact inline transmitter for dry industrial gases, compressed-air dryers, glove boxes and OEM pipelines.
  • Dew point −60 … +60°C, accuracy ±2°C Td
  • Operating temperature −40 … +60°C; 16 bar; IP65; 4–20 mA / 0–5 V / 0–10 V + RS485
HENGKO HG602-G corrosion-resistant compact dew point transmitter, Type A and Type B bodies

HG602-G

Corrosion-Resistant

  • Inline body for HF, chlorine, ammonia, oil mist, salt spray and organic solvents — including battery and chemical lines.
  • Dew point −60 … +20°C, accuracy ±3°C Td
  • Coated stainless housing; IP65; 16 bar; same dual analog + RS485 output set
HENGKO HG602-C minimal-type compact dew point transmitter with optional gas sampling unit

HG602-C

Minimal Type

  • Designed for refrigerated air dryers and compact OEM monitoring, with the tightest Td accuracy in this lineup.
  • Dew point −30 … +50°C, accuracy ±1°C Td
  • Operating temperature −20 … +50°C; Type A body pictured; G1/2" + optional sampling unit

HG808 Series — industrial box-type online dew point transmitters

Aluminium-alloy housing, split probe, local display and keypad, and Modbus-RTU integration. Digital output can report dew point, temperature, humidity and PPM (humidity and PPM for reference only). Transmitter operating range is −20°C…+60°C; measurement ranges differ by model.

HENGKO HG808-D precision online dew point transmitter with aluminium housing, display and a long grid-type split probe

HG808-D

Precision & Stability

  • Box-type transmitter for low-humidity and dry or inert gases — compressed air, semiconductor protective gas and similar service.
  • Dew point −60 … +90°C, accuracy ±2°C Td
  • Temperature range −40 … +90°C; probes 0A#, 0B#, 8A#, 8B#; 16 bar
HENGKO HG808-G corrosion-resistant online dew point transmitter with a long sintered split probe

HG808-G

Corrosion-Resistant

  • 316L probe with a protective coating and IP65 cast-aluminum housing for chemical, pharmaceutical and new-energy processes.
  • Dew point −60 … +20°C, accuracy ±3°C Td
  • Probes 0A# and 8A# only; 16 bar; RS485 + one analog output
HENGKO HG808-A ultra-high-temperature online dew point transmitter with a sintered split probe

HG808-A

Ultra-High Temperature

  • Specified for high-temperature drying, petrochemical and vacuum processes, with a temperature range of 0…+180°C.
  • Dew point −20 … +100°C, accuracy ±3°C Td
  • Temperature range 0 … +180°C; probes 0A#, 0B#, 8A#, 8B#. The catalogue does not state +200°C.

Handheld dew point temperature and humidity meters

The catalogue section “Handheld Dew Point Temperature and Humidity Meter” lists three models. All three include a dew-point range of −30…+80°C. A separate dew-point accuracy is not published. Probe housings are 316L, IP66; probe length can be customised from 30 mm to 545 mm. Live-page SKUs that are not in this catalogue section (for example HG972, HG983, HG984) are not listed here.

HENGKO HG970 handheld dew point temperature and humidity meter with a short replaceable metal probe

HG970

Replaceable Probe Handheld

  • Portable meter with a replaceable probe, USB data recording, and a probe temperature range of −30…+80°C.
  • Dew point −30 … +80°C (Td accuracy not stated)
  • T accuracy ±0.1°C (@20°C); RH ±1.5% RH (@20°C, 20–60% RH)
HENGKO HG981 high-temperature handheld dew point meter with a long thin replaceable probe

HG981

High-Temperature Handheld

  • On-site inspection meter with a long thin probe. Temperature range −30…+120°C; the catalogue highlights +80…+120°C as highly recommended.
  • Dew point −30 … +80°C; 316L / IP66
  • Bluetooth (customisable); 99 data sets. Td accuracy not stated in the catalogue.
HENGKO HG982 split-type handheld dew point meter with a coiled cable and a long external probe

HG982

Split Type Handheld

  • Split-type meter with a coiled cable and a long external probe for ovens, dryers, narrow spaces and equipment cavities.
  • Dew point −30 … +80°C; probe temperature −30 … +120°C
  • USB recording; optional Bluetooth; 316L / IP66. Td accuracy not stated in the catalogue.
Datasheet compare

Compare dew point ranges, accuracy and installation

Figures are taken from the 2026-08-31 English catalogue. Distinctive numbers are highlighted in brand blue. Hover a model name for a product photo; click to enlarge. Click a row to pin it. On small screens, scroll the table horizontally.

Catalogue comparison of HG602, HG808 and handheld dew point instruments
Model Dew point range Accuracy Temperature / operating range Outputs Pressure / installation Key features Typical applications Inquire
−60 … +60°C ±2°C Td Op. temp. −40 … +60°C 4–20 mA / 0–5 V / 0–10 V + RS485 (Modbus-RTU) 16 bar; IP65; G1/2"; Type A or B; flange / sampling expansion
  • Compact pipeline / OEM body
  • Built-in anti-condensation heating
  • Long-term stability <1°C/year
  • DC 10–28 V
  • Compressed-air drying systems
  • Glove boxes and plastic dryers
  • Industrial gases (Ar, N2, O2, NH3, air)
  • OEM equipment integration
−60 … +20°C ±3°C Td Op. temp. −40 … +60°C 4–20 mA / 0–5 V / 0–10 V + RS485 (Modbus-RTU) 16 bar; IP65; G1/2"; Type A or B; coated stainless housing
  • Resists acids, alkalis, salt spray
  • Specified for HF, chlorine, ammonia, oil mist and solvents
  • Fine resolution 0.01 / 0.1°C (key features)
  • Anti-condensation heating
  • Lithium-battery electrolyte / electrode / jelly-roll lines
  • Chemical reactors
  • Food and pharmaceutical drying
  • Compressed-air drying in harsh service
−30 … +50°C ±1°C Td Op. temp. −20 … +50°C 4–20 mA / 0–5 V / 0–10 V + RS485 (Modbus-RTU) 16 bar; IP65; G1/2"; Type A pictured; sampling-unit option
  • Designed for refrigerated air dryers
  • Tightest Td accuracy in this catalogue lineup
  • Anti-condensation heating
  • LED alarm listed as a feature
  • Refrigerated air dryers, oxygen concentrators, air compressors
  • Compressed-air systems
  • OEM equipment integration
−60 … +90°C ±2°C Td Meas. −40 … +90°C
Transmitter op. −20 … +60°C
4–20 mA / 0–5 V / 0–10 V (choose one) + RS485 / Modbus-RTU 16 bar; probes 0A#, 0B#, 8A#, 8B#; M20 / G1/2 / NPT1/2 / M27 / flange
  • Aluminium-alloy housing with display
  • Anti-condensation (stated for this model)
  • T accuracy ±0.1°C (@23°C)
  • Digital T / RH / Td / PPM (RH & PPM for reference)
  • Compressed-air drying, post-treatment monitoring
  • Semiconductor protective gas
  • Air-separation nitrogen purity
  • Food / pharmaceutical protective gas
−60 … +20°C ±3°C Td Meas. −20 … +60°C
Transmitter op. −20 … +60°C
4–20 mA / 0–5 V / 0–10 V (choose one) + RS485 / Modbus-RTU 16 bar; IP65 cast-aluminum housing; probes 0A#, 8A# only
  • 316L with special protective coating
  • Resists acids, alkalis, solvents, salt spray
  • T accuracy ±0.2°C (@23°C)
  • Built-in data logging
  • Lithium-battery electrolyte / coating / jelly-roll
  • Pharmaceutical API drying
  • Chemical reactors / solvent recovery
  • Waste-gas treatment
−20 … +100°C ±3°C Td Meas. 0 … +180°C
Transmitter op. −20 … +60°C
4–20 mA / 0–5 V / 0–10 V (choose one) + RS485 / Modbus-RTU 16 bar; probes 0A#, 0B#, 8A#, 8B#
  • Temperature range 0…+180°C
  • T accuracy ±0.3°C (@85°C)
  • Catalogue does not state +200°C
  • Built-in data logging
  • Pharmaceutical sterilization and drying
  • Petrochemical catalytic cracking
  • Electrode-sheet drying rooms
  • High-temperature vacuum chambers
  • Food dryers / drying rooms
−30 … +80°C Td not stated; T ±0.1°C (@20°C); RH ±1.5% RH Probe temp. −30 … +80°C USB data recording; Bluetooth available on the handheld series Replaceable probe; 316L / IP66 family housing; custom length 30–545 mm
  • One instrument, two identical detachable probes
  • Wet bulb −20…+60°C
  • Sampling 1/s; response <10 s
  • 9 V battery (intro text)
  • Laboratory and production inspection
  • Compressed air and process gases
  • Verification and calibration-style checks
−30 … +80°C Td not stated; T ±0.1°C (@20°C); RH ±1.5% RH Probe temp. −30 … +120°C Bluetooth (customisable); 99 data sets Long thin replaceable probe; 316L / IP66
  • Catalogue highlights +80…+120°C as highly recommended
  • 10 ms calculation (features list)
  • Backlit HD display
  • High-temperature or narrow-space inspection
  • Hygroscopic plastics and semiconductor materials
  • Box-equipment cavities
−30 … +80°C Td not stated; T ±0.1°C (@20°C); RH ±1.5% RH Probe temp. −30 … +120°C (probe only) USB data recording; Bluetooth (customisable) Split probe with coiled cable; 316L / IP66
  • Long external probe for ovens and cavities
  • Sampling 1/s; response <10 s
  • 99 data sets
  • Drying ovens and dryers
  • Semiconductor equipment maintenance
  • Narrow spaces and harsh HVAC sampling

HG808 “temperature range” is the measurement range of the probe; “transmitter operating range” is the specified −20°C…+60°C, 0–95% RH (non-condensing) band in the specification list. HG602 tables list operating temperature rather than a separate temperature-measurement range. Handheld dew-point accuracy is not published in the catalogue. Pressure resistance is 16 bar in the 2026 catalogue (not the 10 bar figure that appeared on an earlier live summary). A power adapter (AC 100–240 V / DC 12 V 1 A) is listed as an optional accessory for bench or debug use.

Probes, fittings and accessories

Specify the probe and the process connection that fit the line

HG808 uses catalogue split probes and threaded or flange fittings. HG602 is an inline G1/2" body — its process connection and Type A / Type B variants are shown separately, not by pasting HG808 probes onto the compact transmitter. A gas sampling kit can be used with either family when the process cannot be measured directly.

HG808 split probes

Applicable probes: HG808-D and HG808-A — 0A#, 0B#, 8A#, 8B#. HG808-G — 0A# and 8A# only. Housing A = 316L sintered; Housing B = 316L grid (for low-dust, low-pollution, high-humidity service that needs a fast response). Assembled photographs of 0A#, 0B#, 8A# and 8B# all appear in the catalogue.

HG808 installation fittings

HG602 process connection and body styles

Series installation drawings: Type A overall length 127 mm, filter section 45 mm, G1/2". Type B body 118 mm, tip section 36 mm, G1/2". Flange or sampling-unit expansion is supported.

Optional accessories

Gas sampling kits let you measure temperature, humidity and dew point indirectly under special conditions such as ultra-high temperature, ultra-high pressure or harsh environments. The inlet can be screwed into the probe or used with a threaded adapter. Stainless steel; various air intakes; adjustable flow rate. A power adapter (AC 100–240 V in, DC 12 V / 1 A out) is listed for quick debugging when no PLC supply is available.

Handheld probe options

Applications

Typical process conditions, matched to a model

Application photographs are taken from the 2026 catalogue or from already-published hengkometer.com process photos. Recommended models follow the catalogue positioning for each condition.

HG602 compact dew point transmitter installed on a stainless gas pipeline with a ball valve

Compressed air and dry industrial gas

Pipeline and dryer skids for compressed air, nitrogen, argon, oxygen and similar dry gases. The catalogue photograph shows an HG602 installed on a stainless gas line.

Recommended: HG602-D · HG808-D

Industrial compressed-air and process equipment for dry-gas dew point monitoring

Dryers, generators and gas delivery

Compressed-air drying systems, plastic-pellet dryers and gas generation or delivery skids — the core industrial-gas use case for the precision D models.

Recommended: HG602-D · HG808-D

Chemical process environment for corrosion-resistant dew point transmitters

Corrosive chemical and solvent service

Chemical reactors, solvent-recovery pipelines and waste-gas treatment, where a coated 316L / corrosion-resistant G model is the catalogue choice.

Recommended: HG602-G · HG808-G

Lithium-battery dry-room production environment

Lithium-battery and new-energy dry rooms

Electrolyte filling, electrode coating and jelly-roll manufacturing, listed as typical applications for both HG602-G and HG808-G.

Recommended: HG602-G · HG808-G

Industrial drying line for high-temperature process dew point monitoring

High-temperature drying and process heat

Industrial drying lines, food dryers, pharmaceutical sterilization and high-temperature vacuum chambers. HG808-A is the ultra-high-temperature transmitter (temperature range 0…+180°C).

Recommended: HG808-A

Packaged refrigerated air dryer and compressor set

Refrigerated dryers and compact OEM

Performance verification of refrigerated air dryers, oxygen concentrators and air compressors — the design case for the minimal-type HG602-C.

Recommended: HG602-C

Laboratory inspection scene from the handheld dew-point catalogue chapter

Portable inspection and laboratory checks

When the job is a walk-around measurement rather than a fixed loop: HG970 for general replaceable-probe inspection, HG981 for higher probe temperature, HG982 for split-probe access into ovens and cavities.

Recommended: HG970 · HG981 · HG982

Outputs and integration

Analog, RS485 Modbus-RTU, and what to confirm per model

Both transmitter families are designed to talk to a PLC or DCS. The exact analog option is chosen at order; confirm it on the quotation. Default baud rate is 9600 bps, with 1200, 2400, 4800, 9600, 19200 and 115200 selectable. Fastest stated response is 1 second, adjustable via PLC.

HENGKO HG808 online dew point transmitter on a cabinet, with an RS485 / Modbus-RTU connection illustrated to a PLC / DCS

RS485 / Modbus-RTU

Digital output on HG602 and HG808 supports Modbus-RTU for interconnection with PLC, DCS and configuration software. HG808 can simultaneously read dew point, temperature, humidity and PPM (humidity and PPM for reference only). Single- and multi-register reading is listed on the HG808 family page. Digital resolution can be 0.1 or 0.01.

Inline dew point probe on process piping, with 4–20 mA, 0–5 V, 0–10 V and RS485 / Modbus-RTU output options illustrated

4–20 mA / 0–5 V / 0–10 V

HG602 lists 4–20 mA / 0–5 V / 0–10 V plus RS485. HG808 lists temperature and dew-point analog output as 4–20 mA / 0–5 V / 0–10 V (choose one of three), with RS485 described on the “Why choose” pages. Analog output is specified with 15-bit resolution on the HG808 family page.

HENGKO HG982 split-type handheld dew point meter with a coiled cable and a long external probe, display reading 52.0 %RH and 28.08 °C

Handheld data and power

HG970 and HG982 list USB data recording; the handheld series can connect to a computer for tables, PDF reports, CSV or Excel. Bluetooth is reserved / customisable, with 99 sets viewable on the instrument and 32,000–64,000 records in memory. Transmitter supply is DC 10–28 V. An optional AC 100–240 V / DC 12 V 1 A adapter is listed for bench debugging.

Specify / OEM

How to specify a dew point transmitter — and what we can customise

A complete inquiry should describe the gas and the installation, not only a model code. The items below are taken from the catalogue customisation notes and the information we need to recommend a configuration.

HG602 compact dew point transmitter installed on a stainless gas pipeline with a ball valve

What to tell us

  • Gas type and any corrosive components (for example HF, NH₃, chlorine, solvents, oil mist or salt spray)
  • Operating pressure (catalogue models are specified up to 16 bar)
  • The dew-point range you need to control or alarm
  • Process / probe temperature, including any continuous high-temperature duty
  • Installation style: compact G1/2" inline, or a box-type split probe
  • Preferred output: 4–20 mA, 0–5 V or 0–10 V, plus RS485 / Modbus-RTU
  • Probe length or type (0A# / 0B# / 8A# / 8B#; handheld 30–545 mm)
  • Whether a gas sampling kit or flange adapter is required
Stainless steel gas sampling kit assembly with fittings and a T-joint

Catalogue customisation

  • HG808 probe structure, shape, length, material and installation method
  • Thread or flange fittings: M20×1.5, G1/2, NPT1/2, M27×2.0, flange
  • Analog output choice and RS485 / Modbus-RTU
  • Corrosion-resistant coatings on the G models
  • HG602 Type A or Type B body (dual connectors and LED on Type B)
  • Optional gas sampling kits (stainless steel, adjustable flow) and the DC 12 V / 1 A debug adapter
  • Handheld Standard or Dust-Proof probes; customisable length 30–545 mm

Start an inquiry

Manufacturer

Why HENGKO

HENGKO manufactures professional dew point transmitters, temperature and humidity transmitters, and handheld dew point meters, and supplies temperature and humidity monitoring solutions for industrial projects.

Manufacturer / OEM

In-house manufacturing and OEM support for industrial dew-point and humidity monitoring projects.

Specify from the catalogue

Probes, outputs (RS485 / Modbus-RTU, 4–20 mA, 0–5 V, 0–10 V), and related options can be specified from the official catalogue range.

Talk to sales

Contact the sales team to discuss your requirements and identify a suitable model.

Brands and organizations shown on this site

Solvay — brand mark shown on hengkometer.com
SGS — brand mark shown on hengkometer.com
P&G — brand mark shown on hengkometer.com
Honeywell — brand mark shown on hengkometer.com
Great Wall — brand mark shown on hengkometer.com
FOXCONN — brand mark shown on hengkometer.com
Emerson — brand mark shown on hengkometer.com
CRRC — brand mark shown on hengkometer.com
CASC — brand mark shown on hengkometer.com
CETC — brand mark shown on hengkometer.com

These logos are existing site assets already shown on hengkometer.com, used here as social proof. They are not a claim of exclusive partnership.

Manufacturing

Our Factory

HENGKO manufactures professional dew point transmitters, temperature and humidity transmitters, and handheld dew point meters, and offers a range of temperature and humidity monitoring solutions.

Products are designed for accuracy and reliability in industrial applications. The team can support a project with a dew point sensor or humidity transmitter from the catalogue range.

Contact HENGKO

Humidity transmitter and sensor packaging by HENGKO
Humidity transmitter and sensor packaging by HENGKO
Humidity transmitter and sensor manufacturer in China, by HENGKO
Humidity transmitter and sensor manufacturer in China, by HENGKO
Temperature and humidity transmitter aging testing at HENGKO
Temperature and humidity transmitter aging testing
Handheld dew point temperature and humidity meter testing at HENGKO
Handheld dew point temperature and humidity meter testing
HENGKO showing temperature and humidity transmitters at a Germany fair
HENGKO showing temperature and humidity transmitters at a Germany fair
HENGKO showing temperature and humidity transmitters at an America fair
HENGKO showing temperature and humidity transmitters at an America fair
FAQ

Questions buyers ask before they specify a dew point transmitter

Direct answers first, then the catalogue detail. If your gas, pressure or temperature sits between two models, send an inquiry and we will recommend a configuration.

An industrial dew point transmitter is a process instrument that measures the dew-point temperature of a gas — the temperature at which moisture begins to condense — and outputs that value for monitoring or control.

HENGKO HG602 and HG808 transmitters are designed for industrial gases and compressed air. Digital output on the HG808 series can report dew point together with temperature, humidity and PPM (humidity and PPM for reference only). Analog and RS485 Modbus-RTU outputs are offered so the reading can go to a PLC or DCS.

Choose HG602 when you need a compact, inline body with a G1/2" process connection for pipeline or OEM installation in a tight space. Choose HG808 when you need an industrial box-type transmitter with a display, a split probe, optional installation fittings, and on-board recording.

Both families include a precision/stable D model, a corrosion-resistant G model, and a specialist variant: HG602-C for refrigerated dryers and higher Td accuracy (±1°C), and HG808-A for ultra-high-temperature processes up to +180°C (temperature range).

Dew point is the temperature at which the water vapour in a gas would begin to condense; relative humidity is the amount of vapour present as a percentage of the saturation amount at the current temperature.

In dry process gases and compressed air, dew point is usually the more useful control variable because it is tied directly to the moisture load, not to the ambient temperature at the sensor. Relative humidity can still be read on these transmitters (on HG808, humidity and PPM are for reference only).

Catalogue dew-point ranges and accuracies are: HG602-D −60…+60°C, ±2°C Td; HG602-G −60…+20°C, ±3°C Td; HG602-C −30…+50°C, ±1°C Td; HG808-D −60…+90°C, ±2°C Td; HG808-G −60…+20°C, ±3°C Td; HG808-A −20…+100°C, ±3°C Td.

Handheld models HG970, HG981 and HG982 list a dew-point range of −30…+80°C. A separate dew-point accuracy is not stated in the catalogue for the handhelds; temperature accuracy is ±0.1°C (@20°C) and humidity accuracy is ±1.5% RH (@20°C, 20–60% RH).

Use a corrosion-resistant G model: HG602-G for compact inline installation, or HG808-G for a box-type transmitter with a split probe.

Both are specified for harsh gases such as HF, chlorine or ammonia (HG602-G) or HF and NH₃ (HG808-G), together with oil mist, salt spray and organic solvents. HG808-G uses 316L stainless steel with a protective coating, IP65-rated cast aluminum housing, and probes 0A# or 8A# only. Confirm the gas composition and pressure (up to 16 bar) when you inquire.

HG808-A is the ultra-high-temperature online dew point transmitter. Its temperature range is 0…+180°C, with a dew-point range of −20…+100°C and accuracy of ±3°C Td.

The transmitter operating range in the specification list is −20°C…+60°C (non-condensing). The sensor is specified for 0…+180°C environments. The 2026 catalogue does not state a short-term +200°C rating. For portable checks at higher probe temperature, HG981 and HG982 list a probe temperature range to +120°C (dew point still −30…+80°C).

HG602 models list 4–20 mA / 0–5 V / 0–10 V plus RS485 (Modbus-RTU). HG808 models list temperature and dew-point analog output as 4–20 mA / 0–5 V / 0–10 V (choose one of three), with RS485 / Modbus-RTU digital output described on the “Why choose” pages.

The exact output set should be confirmed per model when you order. Default baud rate is 9600 bps, with 1200–115200 selectable. Handheld meters offer USB data recording (HG970, HG982) and optional Bluetooth.

HG808 dew-point models use split probes 0A#, 0B#, 8A# and 8B# (HG808-G: 0A# and 8A# only). Housing A is 316L sintered; Housing B is 316L grid. Installation fittings are M20×1.5, G1/2, NPT1/2, M27×2.0 and flange. An optional gas sampling unit can be added.

HG602 uses a G1/2" threaded body and supports flange or sampling-unit expansion. Type A is the compact single-cable body; Type B adds dual aviation connectors and an LED alarm (Type B is pictured for HG602-D and HG602-G; confirm for HG602-C). Handheld probes are Standard Type or Dust-Proof Type, with customisable length 30–545 mm.

Use a handheld meter for on-site inspection, verification and portable sampling rather than continuous pipeline or cabinet mounting.

HG970 is the replaceable-probe calibrator-style meter (probe temperature −30…+80°C). HG981 is the high-temperature handheld (probe temperature to +120°C, long thin probe). HG982 is the split-type meter with a coiled cable and a long external probe, suited to ovens, dryers and narrow spaces. They are not a substitute for a fixed 4–20 mA / RS485 transmitter in a control loop.

Tell us the gas (and any corrosive components), operating pressure, the dew-point range you need to control, the process temperature, the preferred installation (compact G1/2" inline or a box-type split probe), the output signal, and any probe length or fitting you already use.

If you have used the selector on this page, the recommended model and optional configuration are added to the inquiry list automatically. Email sales@hengkometer.com or call +86-755-88823250.

Inquiry

Tell us the condition — we will recommend a configuration

Send a quotation request for one or more dew point transmitters or handheld meters. You can add several models at once. The form is sent to HENGKO sales through the site contact form.

Your inquiry goes to HENGKO sales. Please tick the verification box, then send.