Compact inline, limited space
HG602 is a highly integrated pipeline transmitter with a G1/2" process connection, built for confined industrial installations and OEM equipment.
Select a compact inline HG602, an industrial box-type HG808 with a split probe, or a handheld meter — then inquire with your process conditions.
−60°C Td low-range models to −60°C
16 bar pressure resistance
RS485 + analog Modbus-RTU, 4–20 mA / 0–5 V / 0–10 V
A YouTube video, “How Dew Point Sensors Make Factories Safer!”, can be played in this section. If the player does not load, open https://www.youtube.com/watch?v=PQUK1QSwNd0
An industrial dew point transmitter measures the dew-point temperature of a process gas — the temperature at which moisture would condense — and outputs that value, often together with temperature and humidity, as an analog and/or RS485 Modbus-RTU signal for PLC or DCS monitoring. HENGKO HG602 compact inline transmitters and HG808 box-type transmitters are specified for industrial gases, compressed air and demanding process conditions.
Dry gas, corrosive chemistry and high-temperature processes fail ordinary humidity transmitters in different ways. This range is organised by those conditions, and by whether you need a compact inline body or an industrial box with a split probe.
HG602 is a highly integrated pipeline transmitter with a G1/2" process connection, built for confined industrial installations and OEM equipment.
HG808 uses an aluminium-alloy housing, a split or duct-type probe, a local display and keypad, and on-board recording — suited to cabinets, lines and systems that need a serviceable remote probe.
G models use a corrosion-resistant construction (316L with a protective coating on HG808-G and HG602-G) for acids, alkalis, solvents, salt spray and process gases such as HF or ammonia.
HG808-A is specified for a temperature range of 0…+180°C and a dew-point range of −20…+100°C, for drying rooms, flue-gas related service and high-temperature vacuum work.
Recommended: HG808-A
HG602-C is the minimal-type compact transmitter designed for refrigerated air dryers, with the tightest catalogue Td accuracy in this lineup (±1°C) and a −30…+50°C dew-point range.
Recommended: HG602-C
When you need a meter in the hand rather than a fixed 4–20 mA / RS485 loop, the catalogue lists three dew-point handhelds: replaceable-probe HG970, high-temperature HG981, and split-type HG982.
Start with how you will use it, then the operating condition and installation style. Step 3 only configures probes, fittings or outputs — it does not change the recommended model.
What do you need?
Operating condition and installation style
Recommended model
HG602-D · Precision & Stable Type
Compact inline transmitter for dry industrial gases, compressed-air dryers, glove boxes and OEM pipelines.
Recommended model
HG602-G · Corrosion-Resistant
Compact inline transmitter for HF, chlorine, ammonia, oil mist, salt spray and organic solvents — including lithium-battery and chemical lines.
Recommended model
HG602-C · Minimal Type
Compact transmitter designed for refrigerated air dryers, with the tightest Td accuracy in this catalogue lineup.
Recommended model
HG808-D · Precision & Stability
Box-type online transmitter for low-humidity and dry or inert gases — compressed air, semiconductor protective gas and similar service. Use away from corrosive media, oil or chemical vapours.
Recommended model
HG808-G · Corrosion-Resistant
Box-type transmitter with 316L probe, protective coating and IP65 cast-aluminum housing for chemical, pharmaceutical and new-energy dry processes.
Recommended model
HG808-A · Ultra-High Temperature
Box-type transmitter for high-temperature drying, petrochemical and vacuum processes. Temperature range 0…+180°C.
Recommended model
HG970 · Replaceable Probe Handheld
Portable dew-point meter with a replaceable probe, USB data recording, and a probe temperature range of −30…+80°C. Listed in the catalogue as a handheld temperature and humidity dew point meter (TOC: calibrator).
Recommended model
HG981 · High-Temperature Handheld
Compact handheld for on-site inspection at elevated temperature. Probe temperature range −30…+120°C; the catalogue highlights +80…+120°C as the highly recommended use band.
Recommended model
HG982 · Split Type Handheld
Split-type handheld with a coiled cable and a long external probe for ovens, dryers, narrow spaces and equipment cavities.
Optional configuration — does not change the recommended model
Applicable split probes
Housing A is 316L sintered; Housing B is 316L grid (faster response in low-dust, high-humidity service). HG808-G accepts 0A# and 8A# only. Inapplicable probes are hidden when a model is recommended.
Installation fittings
Accessory
Body style
HG602-C pages show Type A only; the LED alarm is still listed as a feature. Confirm a Type B body with us if you need it on HG602-C. Process connection is G1/2"; flange or sampling-unit expansion is supported.
Analog output (RS485 is included)
Accessory
Handheld probe type
The series is supplied with two identical detachable probes. Probe length can be customised from 30 mm to 545 mm. 316L housing, IP66.
Recommended model
HG602-D · Precision & Stable Type
Compact inline transmitter for dry industrial gases, compressed-air dryers, glove boxes and OEM pipelines.
Recommended model
HG602-G · Corrosion-Resistant
Compact inline transmitter for HF, chlorine, ammonia, oil mist, salt spray and organic solvents — including lithium-battery and chemical lines.
Recommended model
HG602-C · Minimal Type
Compact transmitter designed for refrigerated air dryers, with the tightest Td accuracy in this catalogue lineup.
Recommended model
HG808-D · Precision & Stability
Box-type online transmitter for low-humidity and dry or inert gases — compressed air, semiconductor protective gas and similar service. Use away from corrosive media, oil or chemical vapours.
Recommended model
HG808-G · Corrosion-Resistant
Box-type transmitter with 316L probe, protective coating and IP65 cast-aluminum housing for chemical, pharmaceutical and new-energy dry processes.
Recommended model
HG808-A · Ultra-High Temperature
Box-type transmitter for high-temperature drying, petrochemical and vacuum processes. Temperature range 0…+180°C.
Recommended model
HG970 · Replaceable Probe Handheld
Portable dew-point meter with a replaceable probe, USB data recording, and a probe temperature range of −30…+80°C. Listed in the catalogue as a handheld temperature and humidity dew point meter (TOC: calibrator).
Recommended model
HG981 · High-Temperature Handheld
Compact handheld for on-site inspection at elevated temperature. Probe temperature range −30…+120°C; the catalogue highlights +80…+120°C as the highly recommended use band.
Recommended model
HG982 · Split Type Handheld
Split-type handheld with a coiled cable and a long external probe for ovens, dryers, narrow spaces and equipment cavities.
The 2026 catalogue groups dew-point instruments as compact inline HG602 transmitters, box-type HG808 online transmitters, and handheld dew-point meters. Figures below are taken from that catalogue.
A highly integrated G1/2" pipeline body for confined industrial installations. Type A is the compact single-cable body; Type B adds dual aviation connectors and an LED alarm. All three models list 4–20 mA / 0–5 V / 0–10 V + RS485, IP65 and 16 bar pressure resistance.
HG602-D
HG602-G
HG602-C
Aluminium-alloy housing, split probe, local display and keypad, and Modbus-RTU integration. Digital output can report dew point, temperature, humidity and PPM (humidity and PPM for reference only). Transmitter operating range is −20°C…+60°C; measurement ranges differ by model.
HG808-D
HG808-G
HG808-A
The catalogue section “Handheld Dew Point Temperature and Humidity Meter” lists three models. All three include a dew-point range of −30…+80°C. A separate dew-point accuracy is not published. Probe housings are 316L, IP66; probe length can be customised from 30 mm to 545 mm. Live-page SKUs that are not in this catalogue section (for example HG972, HG983, HG984) are not listed here.
HG970
HG981
HG982
Figures are taken from the 2026-08-31 English catalogue. Distinctive numbers are highlighted in brand blue. Hover a model name for a product photo; click to enlarge. Click a row to pin it. On small screens, scroll the table horizontally.
| Model | Dew point range | Accuracy | Temperature / operating range | Outputs | Pressure / installation | Key features | Typical applications | Inquire |
|---|---|---|---|---|---|---|---|---|
| −60 … +60°C | ±2°C Td | Op. temp. −40 … +60°C | 4–20 mA / 0–5 V / 0–10 V + RS485 (Modbus-RTU) | 16 bar; IP65; G1/2"; Type A or B; flange / sampling expansion |
|
|
||
| −60 … +20°C | ±3°C Td | Op. temp. −40 … +60°C | 4–20 mA / 0–5 V / 0–10 V + RS485 (Modbus-RTU) | 16 bar; IP65; G1/2"; Type A or B; coated stainless housing |
|
|
||
| −30 … +50°C | ±1°C Td | Op. temp. −20 … +50°C | 4–20 mA / 0–5 V / 0–10 V + RS485 (Modbus-RTU) | 16 bar; IP65; G1/2"; Type A pictured; sampling-unit option |
|
|
||
| −60 … +90°C | ±2°C Td | Meas. −40 … +90°C Transmitter op. −20 … +60°C |
4–20 mA / 0–5 V / 0–10 V (choose one) + RS485 / Modbus-RTU | 16 bar; probes 0A#, 0B#, 8A#, 8B#; M20 / G1/2 / NPT1/2 / M27 / flange |
|
|
||
| −60 … +20°C | ±3°C Td | Meas. −20 … +60°C Transmitter op. −20 … +60°C |
4–20 mA / 0–5 V / 0–10 V (choose one) + RS485 / Modbus-RTU | 16 bar; IP65 cast-aluminum housing; probes 0A#, 8A# only |
|
|
||
| −20 … +100°C | ±3°C Td | Meas. 0 … +180°C Transmitter op. −20 … +60°C |
4–20 mA / 0–5 V / 0–10 V (choose one) + RS485 / Modbus-RTU | 16 bar; probes 0A#, 0B#, 8A#, 8B# |
|
|
||
| −30 … +80°C | Td not stated; T ±0.1°C (@20°C); RH ±1.5% RH | Probe temp. −30 … +80°C | USB data recording; Bluetooth available on the handheld series | Replaceable probe; 316L / IP66 family housing; custom length 30–545 mm |
|
|
||
| −30 … +80°C | Td not stated; T ±0.1°C (@20°C); RH ±1.5% RH | Probe temp. −30 … +120°C | Bluetooth (customisable); 99 data sets | Long thin replaceable probe; 316L / IP66 |
|
|
||
| −30 … +80°C | Td not stated; T ±0.1°C (@20°C); RH ±1.5% RH | Probe temp. −30 … +120°C (probe only) | USB data recording; Bluetooth (customisable) | Split probe with coiled cable; 316L / IP66 |
|
|
HG808 “temperature range” is the measurement range of the probe; “transmitter operating range” is the specified −20°C…+60°C, 0–95% RH (non-condensing) band in the specification list. HG602 tables list operating temperature rather than a separate temperature-measurement range. Handheld dew-point accuracy is not published in the catalogue. Pressure resistance is 16 bar in the 2026 catalogue (not the 10 bar figure that appeared on an earlier live summary). A power adapter (AC 100–240 V / DC 12 V 1 A) is listed as an optional accessory for bench or debug use.
HG808 uses catalogue split probes and threaded or flange fittings. HG602 is an inline G1/2" body — its process connection and Type A / Type B variants are shown separately, not by pasting HG808 probes onto the compact transmitter. A gas sampling kit can be used with either family when the process cannot be measured directly.
Applicable probes: HG808-D and HG808-A — 0A#, 0B#, 8A#, 8B#. HG808-G — 0A# and 8A# only. Housing A = 316L sintered; Housing B = 316L grid (for low-dust, low-pollution, high-humidity service that needs a fast response). Assembled photographs of 0A#, 0B#, 8A# and 8B# all appear in the catalogue.
Series installation drawings: Type A overall length 127 mm, filter section 45 mm, G1/2". Type B body 118 mm, tip section 36 mm, G1/2". Flange or sampling-unit expansion is supported.
Gas sampling kits let you measure temperature, humidity and dew point indirectly under special conditions such as ultra-high temperature, ultra-high pressure or harsh environments. The inlet can be screwed into the probe or used with a threaded adapter. Stainless steel; various air intakes; adjustable flow rate. A power adapter (AC 100–240 V in, DC 12 V / 1 A out) is listed for quick debugging when no PLC supply is available.
Application photographs are taken from the 2026 catalogue or from already-published hengkometer.com process photos. Recommended models follow the catalogue positioning for each condition.
Industrial drying lines, food dryers, pharmaceutical sterilization and high-temperature vacuum chambers. HG808-A is the ultra-high-temperature transmitter (temperature range 0…+180°C).
Recommended: HG808-A
Performance verification of refrigerated air dryers, oxygen concentrators and air compressors — the design case for the minimal-type HG602-C.
Recommended: HG602-C
Both transmitter families are designed to talk to a PLC or DCS. The exact analog option is chosen at order; confirm it on the quotation. Default baud rate is 9600 bps, with 1200, 2400, 4800, 9600, 19200 and 115200 selectable. Fastest stated response is 1 second, adjustable via PLC.
Digital output on HG602 and HG808 supports Modbus-RTU for interconnection with PLC, DCS and configuration software. HG808 can simultaneously read dew point, temperature, humidity and PPM (humidity and PPM for reference only). Single- and multi-register reading is listed on the HG808 family page. Digital resolution can be 0.1 or 0.01.
HG602 lists 4–20 mA / 0–5 V / 0–10 V plus RS485. HG808 lists temperature and dew-point analog output as 4–20 mA / 0–5 V / 0–10 V (choose one of three), with RS485 described on the “Why choose” pages. Analog output is specified with 15-bit resolution on the HG808 family page.
HG970 and HG982 list USB data recording; the handheld series can connect to a computer for tables, PDF reports, CSV or Excel. Bluetooth is reserved / customisable, with 99 sets viewable on the instrument and 32,000–64,000 records in memory. Transmitter supply is DC 10–28 V. An optional AC 100–240 V / DC 12 V 1 A adapter is listed for bench debugging.
A complete inquiry should describe the gas and the installation, not only a model code. The items below are taken from the catalogue customisation notes and the information we need to recommend a configuration.
HENGKO manufactures professional dew point transmitters, temperature and humidity transmitters, and handheld dew point meters, and supplies temperature and humidity monitoring solutions for industrial projects.
In-house manufacturing and OEM support for industrial dew-point and humidity monitoring projects.
Probes, outputs (RS485 / Modbus-RTU, 4–20 mA, 0–5 V, 0–10 V), and related options can be specified from the official catalogue range.
Contact the sales team to discuss your requirements and identify a suitable model.










These logos are existing site assets already shown on hengkometer.com, used here as social proof. They are not a claim of exclusive partnership.
HENGKO manufactures professional dew point transmitters, temperature and humidity transmitters, and handheld dew point meters, and offers a range of temperature and humidity monitoring solutions.
Products are designed for accuracy and reliability in industrial applications. The team can support a project with a dew point sensor or humidity transmitter from the catalogue range.
Direct answers first, then the catalogue detail. If your gas, pressure or temperature sits between two models, send an inquiry and we will recommend a configuration.
An industrial dew point transmitter is a process instrument that measures the dew-point temperature of a gas — the temperature at which moisture begins to condense — and outputs that value for monitoring or control.
HENGKO HG602 and HG808 transmitters are designed for industrial gases and compressed air. Digital output on the HG808 series can report dew point together with temperature, humidity and PPM (humidity and PPM for reference only). Analog and RS485 Modbus-RTU outputs are offered so the reading can go to a PLC or DCS.
Choose HG602 when you need a compact, inline body with a G1/2" process connection for pipeline or OEM installation in a tight space. Choose HG808 when you need an industrial box-type transmitter with a display, a split probe, optional installation fittings, and on-board recording.
Both families include a precision/stable D model, a corrosion-resistant G model, and a specialist variant: HG602-C for refrigerated dryers and higher Td accuracy (±1°C), and HG808-A for ultra-high-temperature processes up to +180°C (temperature range).
Dew point is the temperature at which the water vapour in a gas would begin to condense; relative humidity is the amount of vapour present as a percentage of the saturation amount at the current temperature.
In dry process gases and compressed air, dew point is usually the more useful control variable because it is tied directly to the moisture load, not to the ambient temperature at the sensor. Relative humidity can still be read on these transmitters (on HG808, humidity and PPM are for reference only).
Catalogue dew-point ranges and accuracies are: HG602-D −60…+60°C, ±2°C Td; HG602-G −60…+20°C, ±3°C Td; HG602-C −30…+50°C, ±1°C Td; HG808-D −60…+90°C, ±2°C Td; HG808-G −60…+20°C, ±3°C Td; HG808-A −20…+100°C, ±3°C Td.
Handheld models HG970, HG981 and HG982 list a dew-point range of −30…+80°C. A separate dew-point accuracy is not stated in the catalogue for the handhelds; temperature accuracy is ±0.1°C (@20°C) and humidity accuracy is ±1.5% RH (@20°C, 20–60% RH).
Use a corrosion-resistant G model: HG602-G for compact inline installation, or HG808-G for a box-type transmitter with a split probe.
Both are specified for harsh gases such as HF, chlorine or ammonia (HG602-G) or HF and NH₃ (HG808-G), together with oil mist, salt spray and organic solvents. HG808-G uses 316L stainless steel with a protective coating, IP65-rated cast aluminum housing, and probes 0A# or 8A# only. Confirm the gas composition and pressure (up to 16 bar) when you inquire.
HG808-A is the ultra-high-temperature online dew point transmitter. Its temperature range is 0…+180°C, with a dew-point range of −20…+100°C and accuracy of ±3°C Td.
The transmitter operating range in the specification list is −20°C…+60°C (non-condensing). The sensor is specified for 0…+180°C environments. The 2026 catalogue does not state a short-term +200°C rating. For portable checks at higher probe temperature, HG981 and HG982 list a probe temperature range to +120°C (dew point still −30…+80°C).
HG602 models list 4–20 mA / 0–5 V / 0–10 V plus RS485 (Modbus-RTU). HG808 models list temperature and dew-point analog output as 4–20 mA / 0–5 V / 0–10 V (choose one of three), with RS485 / Modbus-RTU digital output described on the “Why choose” pages.
The exact output set should be confirmed per model when you order. Default baud rate is 9600 bps, with 1200–115200 selectable. Handheld meters offer USB data recording (HG970, HG982) and optional Bluetooth.
HG808 dew-point models use split probes 0A#, 0B#, 8A# and 8B# (HG808-G: 0A# and 8A# only). Housing A is 316L sintered; Housing B is 316L grid. Installation fittings are M20×1.5, G1/2, NPT1/2, M27×2.0 and flange. An optional gas sampling unit can be added.
HG602 uses a G1/2" threaded body and supports flange or sampling-unit expansion. Type A is the compact single-cable body; Type B adds dual aviation connectors and an LED alarm (Type B is pictured for HG602-D and HG602-G; confirm for HG602-C). Handheld probes are Standard Type or Dust-Proof Type, with customisable length 30–545 mm.
Use a handheld meter for on-site inspection, verification and portable sampling rather than continuous pipeline or cabinet mounting.
HG970 is the replaceable-probe calibrator-style meter (probe temperature −30…+80°C). HG981 is the high-temperature handheld (probe temperature to +120°C, long thin probe). HG982 is the split-type meter with a coiled cable and a long external probe, suited to ovens, dryers and narrow spaces. They are not a substitute for a fixed 4–20 mA / RS485 transmitter in a control loop.
Tell us the gas (and any corrosive components), operating pressure, the dew-point range you need to control, the process temperature, the preferred installation (compact G1/2" inline or a box-type split probe), the output signal, and any probe length or fitting you already use.
If you have used the selector on this page, the recommended model and optional configuration are added to the inquiry list automatically. Email sales@hengkometer.com or call +86-755-88823250.
Product pages and condition hubs for the models and applications on this page.
Send a quotation request for one or more dew point transmitters or handheld meters. You can add several models at once. The form is sent to HENGKO sales through the site contact form.
WhatsApp us